Yayın:
Prediction of dielectric parameters of an aged mv cable: A comparison of curve fitting, decision tree and artificial neural network methods

dc.contributor.authorArikan, Oktay
dc.contributor.authorUydur, Cihat Cagdas
dc.contributor.authorKumru, Celal Fadil
dc.date.accessioned2026-06-27T14:41:37Z
dc.date.issued2022
dc.description.abstractIn most dielectric diagnosis studies on medium voltage cables, aging methods, which requires quite long measurement durations, are preferred and dielectric performance of cable is generally measured at the end of the test period. In addition, changes that occur during the aging cycle should be investigated. Predicting the future performance of a cable by using dielectric parameters measured during the aging cycle is quite important in terms of estimating possible failures. In this regard, the effectiveness of interpolation and extrapolation methods commonly used in the literature should be investigated in order to shorten aging durations and to predict future insulation performance. In this study, 12/20.8 kV rated voltage and XLPE insulated medium voltage cable was aged with 60 kV (5 center dot U-0) overvoltage for 80 cycles of 15 min. After each aging cycle, dielectric parameters (dissipation factor (tan delta), dielectric losses (P-k) and capacitance (C) were measured at rated voltage and mains frequency. Following the measurements, interpolation and extrapolation analyses were performed using artificial neural network (ANN), decision tree (DT) and curve fitting (CF) methods. As a result, interpolation and extrapolation performances of methods are comparatively discussed and introduced. It has been determined that ANN algorithm is the most successful method.en
dc.description.sponsorshipScientific Research Project Coordinator of Yildiz Technical University [FDK2020-3897]
dc.description.sponsorshipYildiz Technical University
dc.description.urihttps://doi.org/10.1016/j.epsr.2022.107892
dc.identifier.doi10.1016/j.epsr.2022.107892
dc.identifier.eissn1873-2046
dc.identifier.issn0378-7796
dc.identifier.urihttps://hdl.handle.net/20.500.14981/63600
dc.identifier.volume208
dc.identifier.wos000865738400009
dc.language.isoeng
dc.publisherELSEVIER SCIENCE SA
dc.relation.ispartofELECTRIC POWER SYSTEMS RESEARCH
dc.subjectDissipation factor
dc.subjectXLPE cable
dc.subjectOvervoltage
dc.subjectAging
dc.subjectInterpolation
dc.subjectExtrapolation
dc.subjectMEDIUM-VOLTAGE
dc.subjectINSULATION
dc.subjectEngineering
dc.titlePrediction of dielectric parameters of an aged mv cable: A comparison of curve fitting, decision tree and artificial neural network methods
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar