Yayın:
Performance evaluation of hot-wall condenser in a domestic refrigerator

dc.contributor.authorPeker, Gokmen
dc.contributor.authorOzkan, Derya Burcu
dc.date.accessioned2026-06-27T14:53:54Z
dc.date.issued2023
dc.description.abstractIn this study, the heat transfer performance of a hot-wall condenser, which is affected by design parameters, is investigated. In this study, the pipe section form (O/D) variation, which has not been examined so far, is used as a design parameter for condenser performance. Incorporating the specified design parameters, 12 different condenser samples were manufactured. Additionally, a simulation model regarding with the thermal effects was designed for comparing the outputs of experimental results. The parameters are outer diameter of the condenser pipe (4.0 and 4.76 mm), condenser pipe pitch (20, 40, and 60 mm), the section form (O/D) of condenser pipe, and the refrigerant mass flow rate in flow. The results revealed significant findings regarding the impact of different design parameters on the heat transfer rate of the condenser. Specifically, increasing the condenser pipe diameter led to an average heat transfer rate increase of 8.9% and 5.2% by increasing flow rates as double, respectively. The pipe pitch was found to have a notable effect on the heat transfer rates, resulting in average increases of 213%, 47%, and 313% for the 20-40 mm, 40-60 mm, and 20-60 mm transitions, respectively. Specifically, the novel output is the transition from O-to-D pipe configuration, resulting in a maximum 3% increase in the total heat transfer rate.en
dc.description.urihttps://doi.org/10.1016/j.applthermaleng.2023.121137
dc.identifier.doi10.1016/j.applthermaleng.2023.121137
dc.identifier.eissn1873-5606
dc.identifier.issn1359-4311
dc.identifier.urihttps://hdl.handle.net/20.500.14981/65964
dc.identifier.volume233
dc.identifier.wos001043766100001
dc.language.isoeng
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD
dc.relation.ispartofAPPLIED THERMAL ENGINEERING
dc.subjectHot-wall condenser
dc.subjectRefrigerator
dc.subjectHeat transfer
dc.subjectPipe form
dc.subjectExperimental tests
dc.subjectHeat transfer model
dc.subjectNATURAL-CONVECTION
dc.subjectThermodynamics
dc.subjectEnergy & Fuels
dc.subjectEngineering
dc.subjectMechanics
dc.titlePerformance evaluation of hot-wall condenser in a domestic refrigerator
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar