Yayın:
Coated Copper Wire Calcium Selective Microelectrode for Applications in Dental Medicine

dc.contributor.authorTotu, Eugenia Eftimie
dc.contributor.authorIsildak, Ibrahim
dc.contributor.authorTavukcuoglu, Ozlem
dc.contributor.authorAgir, Ismail
dc.contributor.authorYildirim, Ridvan
dc.contributor.authorNigde, Mustafa
dc.contributor.authorNechifor, Aurelia Cristina
dc.contributor.authorCristache, Corina Marilena
dc.date.accessioned2026-06-27T14:15:52Z
dc.date.issued2018
dc.description.abstractA coated wire calcium selective microelectrode for biological use was developed, comprising a PVC selective matrix containing calcium ionophore IV coated on copper wire, previously covered with a solid-state contact mixture. The obtained calcium microsensor presented a Nernstian answer in a concentration range of 10(-1) to 10(6) mol/L. The selectivity coefficients over the main interfering ions of biological interest proved that the calcium microelectrode is highly selective. Also, the response time (6s) and repeatability have been determined. The pH variation did not significantly modify the calcium microelectrode answer, being stable over the pH range (6.7-7.3) of interest. The obtained calcium microelectrode is simple, inexpensive and able to give reliable electrochemical response, recommending itself as a solution for assessing the level of inorganic ions of the gingival crevicular fluid and saliva. fluiden
dc.description.sponsorshipRomanian National Authority for Scientific Research and Innovation, CCCDI - UEFISCDI within PNCDI III [39/2018]
dc.description.sponsorshipScientific and Technological Research Council of Turkey (TUBITAK) [BIYOTEG-9170032]
dc.description.sponsorshipRomanian National Authority for Scientific Research and Innovation, CCDI-UEFISCDI within PNCDI III [30/2016]
dc.identifier.endpage4117
dc.identifier.issn0034-7752
dc.identifier.issue11
dc.identifier.startpage4113
dc.identifier.urihttps://hdl.handle.net/20.500.14981/58609
dc.identifier.volume69
dc.identifier.wos000451931500054
dc.language.isoeng
dc.publisherREVISTA CHIMIE SRL
dc.relation.ispartofREVISTA DE CHIMIE
dc.subjectcalcium microsensor
dc.subjectcoated wire microsensor
dc.subjectsolid-state contact mixture
dc.subjectPVC selective mixture
dc.subjectgingival crevicular fluid
dc.subjectELECTRODES
dc.subjectChemistry
dc.subjectEngineering
dc.titleCoated Copper Wire Calcium Selective Microelectrode for Applications in Dental Medicine
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar