Yayın:
Comparison of three different calibration methods and quadruple isotope dilution strategy to design more accurate quantitation method for the determination of monuron in potato flour samples by HPLC-MS/MS

dc.contributor.authorBodur, Suleyman
dc.contributor.authorBodur, Sezin Erarpat
dc.contributor.authorCosar, Beste
dc.contributor.authorGunkara, Omer Tahir
dc.contributor.authorBakirdere, Sezgin
dc.date.accessioned2026-06-27T15:25:21Z
dc.date.issued2026
dc.description.abstractA highly accurate and precise quadruple isotope dilution (ID4) strategy was employed for the determination of monuron in potato flour samples. Isotopic compositions were monitored by tandem mass spectrometry (MS/MS). Isotopically labelled monuron substance (monuron-d6) was synthesized in our research laboratory. After optimizing HPLC-MS/MS system, limit of detection (LOD), limit of quantitation (LOQ) and linear working range (LWR) were figured out as 25.28 ng/kg, 84.27 ng/kg and 0.08-27.55 mu g/kg, respectively. ID4 method was carried out by spiked potato flour samples. Percent recovery results (%RRs) for HPLC-ID4-MS/MS system were varied from 99.0 % to 101.7 % with low standard deviation values (1.2-2.3 %). HPLC-ID4-MS/MS method gave excellent accuracy and precision to determine monuron at trace levels in potato flour samples when compared to external, internal and matrix matching calibration strategies. According to the current literature, no study has been employed to determine monuron in potato flour samples by the HPLC-ID4-MS/MS system.en
dc.description.urihttps://doi.org/10.1016/j.foodchem.2025.147348
dc.identifier.doi10.1016/j.foodchem.2025.147348
dc.identifier.eissn1873-7072
dc.identifier.issn0308-8146
dc.identifier.pubmed41344252
dc.identifier.urihttps://hdl.handle.net/20.500.14981/70787
dc.identifier.volume499
dc.identifier.wos001635750500001
dc.language.isoeng
dc.publisherELSEVIER SCI LTD
dc.relation.ispartofFOOD CHEMISTRY
dc.subjectMonuron
dc.subjectMonuron- d 6
dc.subjectHPLC-MS/MS
dc.subjectQuadruple isotope dilution
dc.subjectPotato flour
dc.subjectCalibration methods
dc.subjectPERFORMANCE LIQUID-CHROMATOGRAPHY
dc.subjectLABELED INTERNAL STANDARDS
dc.subjectPHENYLUREA HERBICIDES
dc.subjectMASS-SPECTROMETRY
dc.subjectUV
dc.subjectQUANTIFICATION
dc.subjectWATER
dc.subjectEXTRACTION
dc.subjectChemistry
dc.subjectFood Science & Technology
dc.subjectNutrition & Dietetics
dc.titleComparison of three different calibration methods and quadruple isotope dilution strategy to design more accurate quantitation method for the determination of monuron in potato flour samples by HPLC-MS/MS
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar