Yayın: Case studies on local mixed convection heat transfer coefficients along a radiant heated wall subjected to displacement ventilation
| dc.contributor.author | Camci, Muhammet | |
| dc.contributor.author | Karakoyun, Yakup | |
| dc.contributor.author | Acikgoz, Ozgen | |
| dc.contributor.author | Dalkilic, Ahmet Selim | |
| dc.date.accessioned | 2026-06-27T14:54:46Z | |
| dc.date.issued | 2023 | |
| dc.description.abstract | As the demand for energy-efficient air conditioning systems enabling thermal comfort criteria increases, the research into innovative systems that combine displacement ventilation and radiant heating is being more up-to-date. This work discusses local mixed convection heat transfer coefficients over a radiant heated wall in an experimental room coupled with displacement ventilation provided by a floor level nozzle. In the experimental chamber, the air enters the room either from the floor level of the analyzed heated wall as in scenario 1 or the opposite wall in scenario 2 in the upward direction. The intervals of air inlet temperature and velocity are set between 13-27 & DEG;C and 0-2.5 ms(-1), respectively. The obtained data have been analyzed from a physical point of view, and four correlations having R-sq. numbers of 0.93, 0.94, 0.94, and 0.98 have been developed for the local mixed convective heat transfer coefficients along a heated wall. The alterations of local convection heat transfer coefficients along an examined radiant heated wall affected by a slot diffuser delivering a lowest air inlet velocity of 0.5 ms(-1) and highest air inlet velocity of 2.5 ms(-1) are gained in the intervals of 2-5.8 Wm(-2) K-1 and 2.5-10 W m(-2) K-1, in turn. | en |
| dc.description.sponsorship | YTU Scientific Research Projects Coordination Department [FCD-2022-5092] | |
| dc.description.uri | https://doi.org/10.1007/s10973-023-12262-6 | |
| dc.identifier.doi | 10.1007/s10973-023-12262-6 | |
| dc.identifier.eissn | 1588-2926 | |
| dc.identifier.endpage | 7854 | |
| dc.identifier.issn | 1388-6150 | |
| dc.identifier.issue | 15 | |
| dc.identifier.startpage | 7845 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14981/66125 | |
| dc.identifier.volume | 148 | |
| dc.identifier.wos | 001023269000022 | |
| dc.language.iso | eng | |
| dc.publisher | SPRINGER | |
| dc.relation.ispartof | JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY | |
| dc.subject | Local convective heat transfer coefficient | |
| dc.subject | Mixed convection | |
| dc.subject | Radiant heated wall | |
| dc.subject | Displacement ventilation | |
| dc.subject | Temperature gradient | |
| dc.subject | ROOM | |
| dc.subject | Thermodynamics | |
| dc.subject | Chemistry | |
| dc.title | Case studies on local mixed convection heat transfer coefficients along a radiant heated wall subjected to displacement ventilation | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| local.import.source | WOS |