Yayın:
Effect of the low-intensity pulsed ultrasound therapy on healing of Achilles tendinopathy in a rat model

dc.contributor.authorKurtulmus, Tuhan
dc.contributor.authorCelebi, Mehmet Emin
dc.contributor.authorBektas, Ebubekir
dc.contributor.authorArican, Cigdem Dicle
dc.contributor.authorKucukyildirim, Bedri Onur
dc.contributor.authorDemirkol, Metehan
dc.date.accessioned2026-06-27T15:09:55Z
dc.date.issued2024
dc.description.abstractObjective: This study aimed to investigate the effect of the low -intensity pulsed ultrasound (LIPUS) on the healing of Achilles tendinopathy in a rat model induced by type 1 collagenase. Methods: The study was conducted on 144 Achilles tendons of 72 Wistar albino female rats with typical activity and weighing 300-350 g. The model of Achilles tendinopathy was created by injecting type 1 collagenase. According to the sampling time, 4 groups served as the control group, while 8 groups received treatment at varying periods. Low -intensity pulsed ultrasound therapy was initiated in 8 groups at 1, 7, and 15 days. Treatment was extended for 1 and 2 weeks. Achilles tendons were removed from the treatment and control groups on the 15th, 21st, 30th, and 45th days for biomechanical and pathologic examination. Results: Compared to the control groups, LIPUS treatment administered in the first days of the proliferation phase increased tensile strength by approximately 30%, modulus of elasticity by approximately 53%, fibrillar appearance by 53%, and inflammation by 53%-33% in a shorter time. It was also demonstrated that starting treatment in the first days of the proliferation phase resulted in comparable success even with 1 -week treatment compared to 2 -week treatment. Conclusion: Low -intensity pulsed ultrasound therapy can provide positive results in managing Achilles tendinopathy in the rat model. Its capacity to shorten recuperation time has piqued the interest of conservative treatment approaches. As a result, more clinical research is required.en
dc.description.urihttps://doi.org/10.5152/j.aott.2024.23157
dc.identifier.doi10.5152/j.aott.2024.23157
dc.identifier.eissn2589-1294
dc.identifier.issn1017-995X
dc.identifier.issue2
dc.identifier.urihttps://hdl.handle.net/20.500.14981/68457
dc.identifier.volume58
dc.identifier.wos001246424400005
dc.language.isoeng
dc.publisherTURKISH ASSOC ORTHOPAEDICS TRAUMATOLOGY
dc.relation.ispartofACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA
dc.rightsopenAccess
dc.subjectLow-intensity pulsed ultrasound
dc.subjectRat
dc.subjectCollagenase type 1
dc.subjectTendinopathy
dc.subjectTEMPERATURE-CHANGES
dc.subjectTENDON
dc.subjectREPAIR
dc.subjectOrthopedics
dc.titleEffect of the low-intensity pulsed ultrasound therapy on healing of Achilles tendinopathy in a rat model
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar