Yayın: Traceable and accurate quantification of iron in seawater using isotope dilution calibration strategies by triple quadrupole ICP-MS/MS: Characterization measurements of iron in a candidate seawater CRM
| dc.contributor.author | An, Betul | |
| dc.contributor.author | Can, Suleyman Z. | |
| dc.contributor.author | Bakirdere, Sezgin | |
| dc.date.accessioned | 2026-06-27T14:29:49Z | |
| dc.date.issued | 2020 | |
| dc.description.abstract | Accurate quantification of iron is crucial for the characterization of a candidate seawater certified reference material. Isotope dilution mass spectrometry as a primary method is one of the option for this purpose. In this study, triethylamine (TEA) assisted Mg(OH)(2) co-precipitation is developed and combined with isotope dilution mass spectrometry for the characterization of candidate certified reference material, UME CRM 1206. The analytical protocol of co-precipitation was optimized to achieve reproducible yields of similar to 100% Fe with high salt rejection (residual salinity similar to 0.003%). Three calibration strategies, single, double and triple isotope dilution mass spectrometry (IDMS) coupled with co-precipitation were investigated in terms of metrological aspects. The determination of Fe was carried out by ICP-MS with tandem configuration (ICP-MS/MS) using NH3/He cell gas which was optimized for the minimum background equivalence concentration to be able to measure highly accurate Fe-56/Fe-57 ratio with the highest possible sensitivity. The background corrected typical procedural blank levels and limit of detection calculated based on three times the standard deviation of blanks were found as 9 ng/kg (0.16 nM) and 11 ng/kg (0.20 nM) for single IDMS, respectively. Trueness of the developed analytical methods has been demonstrated using CASS-6 and NMIA MX014 with complete and very precise recoveries. SI-traceable values with combined uncertainty (k = 2) were obtained for single, double and triple IDMS as (12.70 +/- 0.16) ng/g, (12.728 +/- 0.084) ng/g and (12.732 +/- 0.062) ng/g, respectively. The relative combined uncertainty for each approach was calculated as 0.64%, 0.33% and 0.24%, respectively. | en |
| dc.description.uri | https://doi.org/10.1016/j.talanta.2019.120503 | |
| dc.identifier.doi | 10.1016/j.talanta.2019.120503 | |
| dc.identifier.eissn | 1873-3573 | |
| dc.identifier.issn | 0039-9140 | |
| dc.identifier.pubmed | 31892083 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14981/61294 | |
| dc.identifier.volume | 209 | |
| dc.identifier.wos | 000509632900022 | |
| dc.language.iso | eng | |
| dc.publisher | ELSEVIER | |
| dc.relation.ispartof | TALANTA | |
| dc.subject | Isotope dilution mass spectrometry | |
| dc.subject | Single dilution | |
| dc.subject | Double dilution | |
| dc.subject | Triple dilution | |
| dc.subject | Seawater | |
| dc.subject | Iron | |
| dc.subject | Triethylamine | |
| dc.subject | Mg(OH)(2) co-precipitation | |
| dc.subject | PLASMA-MASS SPECTROMETRY | |
| dc.subject | REDUCED GRAPHENE OXIDE | |
| dc.subject | DETECTOR DEAD-TIME | |
| dc.subject | VOLTAMMETRIC DETERMINATION | |
| dc.subject | CHELATING RESIN | |
| dc.subject | DISSOLVED IRON | |
| dc.subject | METALS | |
| dc.subject | FE | |
| dc.subject | PRECONCENTRATION | |
| dc.subject | ELEMENTS | |
| dc.subject | Chemistry | |
| dc.title | Traceable and accurate quantification of iron in seawater using isotope dilution calibration strategies by triple quadrupole ICP-MS/MS: Characterization measurements of iron in a candidate seawater CRM | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| local.import.source | WOS |