Yayın:
Preparation of electrochemically treated nanoporous pencil-graphite electrodes for the simultaneous determination of Pb and Cd in water samples

dc.contributor.authorDonmez, Koray B.
dc.contributor.authorCetinkaya, Ebru
dc.contributor.authorDeveci, Seda
dc.contributor.authorKaradag, Sevinc
dc.contributor.authorSahin, Yucel
dc.contributor.authorDogu, Mustafa
dc.date.accessioned2026-06-27T14:06:14Z
dc.date.issued2017
dc.description.abstractA simple and rapid analytical method of determining Pb2+ and Cd2+ in water samples using an electrochemically pretreated pencil-graphite electrode (EP-PGE) is proposed for the first time in the literature. An electrochemically pretreated pencil-graphite electrode was prepared by performing potential cycling between -0.3 V and 2.0 V in 0.1 mol L-1 H3PO4 solution to improve its ability to electrochemically sense Pb2+ and Cd2+ ions. Square-wave anodic stripping voltammetry (SWASV) was used as the electroanalytical method. The electroanalytical parameters that influence the stripping determination of Pb2+ and Cd2+ were optimized based on experimental results. The magnitude of the peak oxidation current was adjusted in order to optimize the value of each parameter. Applying the resulting disposable electrode under the optimized conditions led to good selectivity and sensitivity in the determination of Pb2+ and Cd2+ ions. Interference from coexisting ions was also investigated. The resulting sensor was successfully tested by applying it to a standard reference water sample. Under the optimized conditions, the limits of detection were 0.46 mu g L-1 for Pb2+ and 1.11 mu g L-1 for Cd2+ using the electrode. Relative standard deviations (%RSD) were 2.76 for Pb2+ and 2.85 for Cd2+. The linear working ranges of the electrode for Pb2+ and Cd2+ ion detection were 5-45 mu g L-1 and 10-40 mu g L-1, respectively.en
dc.description.urihttps://doi.org/10.1007/s00216-017-0426-3
dc.identifier.doi10.1007/s00216-017-0426-3
dc.identifier.eissn1618-2650
dc.identifier.endpage4837
dc.identifier.issn1618-2642
dc.identifier.issue20
dc.identifier.pubmed28664333
dc.identifier.startpage4827
dc.identifier.urihttps://hdl.handle.net/20.500.14981/57037
dc.identifier.volume409
dc.identifier.wos000406146800015
dc.language.isoeng
dc.publisherSPRINGER HEIDELBERG
dc.relation.ispartofANALYTICAL AND BIOANALYTICAL CHEMISTRY
dc.subjectElectrochemical pretreatment
dc.subjectNanoporous pencil graphite electrode
dc.subjectDetermination of Pb and Cd
dc.subjectVoltammetry
dc.subjectDetermination of heavy metal
dc.subjectANODIC-STRIPPING VOLTAMMETRY
dc.subjectGLASSY-CARBON ELECTRODE
dc.subjectTRACE HEAVY-METALS
dc.subjectTAP WATER
dc.subjectPB(II)
dc.subjectLEAD
dc.subjectCD(II)
dc.subjectSOIL
dc.subjectZN
dc.subjectCU
dc.subjectBiochemistry & Molecular Biology
dc.subjectChemistry
dc.titlePreparation of electrochemically treated nanoporous pencil-graphite electrodes for the simultaneous determination of Pb and Cd in water samples
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar