Yayın:
Sensitive Determination of 4-n-Nonylphenol in Domestic Wastewater and Liquid Detergent by Binary Solvent Microextraction (BSME) and Gas Chromatography-Mass Spectrometry (GC-MS) with Matrix Matching Calibration

dc.contributor.authorErarpat, Sezin
dc.contributor.authorBodur, Suleyman
dc.contributor.authorChormey, Dotse Selali
dc.contributor.authoroz, Ersoy
dc.contributor.authorBakirdere, Sezgin
dc.date.accessioned2026-06-27T14:37:14Z
dc.date.issued2022
dc.description.abstractBinary solvent microextraction (BSME) coupled to gas chromatography-mass spectrometry (GC-MS) was employed to determine 4-n-nonylphenol in domestic wastewater and detergent. The developed BSME method was applied to obtain lower detection limits by preconcentrating the analyte before determination by GC-MS. Relevant parameters of the extraction method, including the binary solvent volume, dispersive solvent volume, and vortex period, were optimized using Box-Behnken Design. Under the optimum conditions, the limit of detection (LOD), limit of quantitation, and linear dynamic range were 0.6, 2.0, and 2.0 to 100 ng g(-1), respectively. The extraction procedure provided an approximate 470-fold enhancement in the detection power. Recovery experiments were performed for spiked wastewater and detergent by performing matrix matching calibration. The recoveries obtained by BSME-GC-MS for wastewater and detergent were between 94 and 103% and 91 and 109%, respectively.en
dc.description.urihttps://doi.org/10.1080/00032719.2021.1985511
dc.identifier.doi10.1080/00032719.2021.1985511
dc.identifier.eissn1532-236X
dc.identifier.endpage1092
dc.identifier.issn0003-2719
dc.identifier.issue7
dc.identifier.startpage1080
dc.identifier.urihttps://hdl.handle.net/20.500.14981/62758
dc.identifier.volume55
dc.identifier.wos000709215100001
dc.language.isoeng
dc.publisherTAYLOR & FRANCIS INC
dc.relation.ispartofANALYTICAL LETTERS
dc.subject4-n-nonylphenol
dc.subjectbinary solvent microextraction (BSME)
dc.subjectenvironmental chemistry
dc.subjectgas chromatography-mass spectrometry (GC-MS)
dc.subjectwater quality
dc.subjectSOLID-PHASE MICROEXTRACTION
dc.subjectBISPHENOL-A
dc.subjectNONYLPHENOL
dc.subjectPESTICIDES
dc.subjectSAMPLES
dc.subjectDESIGN
dc.subjectRIVER
dc.subjectChemistry
dc.titleSensitive Determination of 4-n-Nonylphenol in Domestic Wastewater and Liquid Detergent by Binary Solvent Microextraction (BSME) and Gas Chromatography-Mass Spectrometry (GC-MS) with Matrix Matching Calibration
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar