Yayın:
An accurate determination method for cobalt in sage tea and cobalamin: Slotted quartz tube-flame atomic absorption spectrometry after preconcentration with switchable liquid-liquid microextraction using a Schiff base

dc.contributor.authorYazici, Elif
dc.contributor.authorFirat, Merve
dc.contributor.authorChormey, Dotse Selali
dc.contributor.authorBakirdere, Emine Gulhan
dc.contributor.authorBakirdere, Sezgin
dc.date.accessioned2026-06-27T14:17:24Z
dc.date.issued2020
dc.description.abstractThis study reports a stepwise optimization of switchable liquid-liquid microextraction (SLLME) for cobalt determination by flame atomic absorption spectrometry (FAAS) coupled with a slotted quartz tube (SQT). The main purpose of this study was to develop an accurate and sensitive analytical method for cobalt. Extraction method was used to separate and preconcentrate cobalt from sage tea and vitamin B12 samples after complexing with a Schiff base ligand. 107.7 folds enhancement in detection power under the optimum conditions was recorded with respect to direct FAAS. This enhancement correlated to 3.1 mu g/L limit of detection and 10 mu g/L limit of quantification. The SLLME-SQT-FAAS method was linear over a broad concentration range and low % RSD values established high precision for the method. Appreciable percent recovery results (94-108%) obtained from spiked sage sample and from cobalamin also validated the accuracy of the method.en
dc.description.sponsorshipScientific and Technological Research Council of Turkey (TUBITAK) with the TUBITAK2209 project [1919B011701470]
dc.description.urihttps://doi.org/10.1016/j.foodchem.2019.125336
dc.identifier.doi10.1016/j.foodchem.2019.125336
dc.identifier.eissn1873-7072
dc.identifier.issn0308-8146
dc.identifier.pubmed31419772
dc.identifier.urihttps://hdl.handle.net/20.500.14981/58859
dc.identifier.volume302
dc.identifier.wos000483991900001
dc.language.isoeng
dc.publisherELSEVIER SCI LTD
dc.relation.ispartofFOOD CHEMISTRY
dc.subjectCobalt
dc.subjectFlame atomic absorption spectrometry
dc.subjectSwitchable liquid-liquid microextraction
dc.subjectSlotted quartz tube
dc.subjectExperimental design
dc.subjectSchiff base ligand
dc.subjectPHASE MICROEXTRACTION
dc.subjectWATER SAMPLES
dc.subjectSOLVENT
dc.subjectNICKEL
dc.subjectSELENIUM
dc.subjectFOOD
dc.subjectChemistry
dc.subjectFood Science & Technology
dc.subjectNutrition & Dietetics
dc.titleAn accurate determination method for cobalt in sage tea and cobalamin: Slotted quartz tube-flame atomic absorption spectrometry after preconcentration with switchable liquid-liquid microextraction using a Schiff base
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar