Yayın:
BOX-BEHNKEN DESIGN OPTIMIZATION OF ELECTRO-FENTON/-PERSULFATE PROCESSES FOLLOWING THE ACIDIFICATION FOR TSS REMOVAL FROM BIODIESEL WASTEWATER

dc.contributor.authorYazici Guvenc, Senem
dc.contributor.authorVarank, Gamze
dc.date.accessioned2026-06-27T14:32:26Z
dc.date.issued2020
dc.description.abstractIn this study, biodiesel wastewater was first subjected to acidification process, and then in the second step, Electro-Fenton (EF) and Electro-Persulfate (EP) processes were applied as treatment method. Box-Behnken Design (BBD) method was used for the optimization of process parameters in total suspended solids (TSS) removal from biodiesel wastewater, and for formation of mathematical model. Current (1-4 A), H2O2/ Chemical Oxygen Demand (COD) (0.4-2.0) and time (15-45 min) for EF process and current (1-4 A), persulfate/COD (1-5) and time (15-45 min) for EP process were selected as the independent variables whereas TSS removal was selected as response. Optimum conditions were determined by means of variance analysis (ANOVA), and response surface graphics, and second degree regression models were developed by the use of Design Expert 11.0.1.0 software program for the estimation of TSS removal. According to the results obtained by the application of response surface method, correlation coefficients of second degree polynomial equation were determined as very high for the TSS removal of both processes, and the model's compliance was observed. Model's correlation coefficient (R-2) for EF and EP processes were determined as 92.67% and 93.03% respectively. High R-2 values indicate that the experimental data are in conformity with the model's results. As the result of experimental study actualized under optimum conditions determined by the model for obtaining maximum contaminant removal, TSS removal efficiencies were determined as 98.9% and 90.6% respectively for the EF and EP processes. EF and EP processes, following the acidification process, are suitable treatment alternatives for the removal of TSS from biodiesel wastewater, and BBD method is suitable for the optimization of process.en
dc.description.sponsorshipYildiz Technical University-The Scientific Research Projects Coordinatorship [FBA-2020-3906]
dc.identifier.eissn1304-7191
dc.identifier.endpage1780
dc.identifier.issn1304-7205
dc.identifier.issue4
dc.identifier.startpage1767
dc.identifier.urihttps://hdl.handle.net/20.500.14981/61824
dc.identifier.volume38
dc.identifier.wos000603605300010
dc.language.isoeng
dc.publisherYILDIZ TECHNICAL UNIV
dc.relation.ispartofSIGMA JOURNAL OF ENGINEERING AND NATURAL SCIENCES-SIGMA MUHENDISLIK VE FEN BILIMLERI DERGISI
dc.subjectBiodiesel wastewater
dc.subjectelectro-fenton
dc.subjectelectro-persulfate
dc.subjectBox-Behnken Design
dc.subjectDEGRADATION
dc.subjectOXIDATION
dc.subjectELECTROCOAGULATION
dc.subjectCOAGULATION
dc.subjectLEACHATE
dc.subjectCOD
dc.subjectEngineering
dc.titleBOX-BEHNKEN DESIGN OPTIMIZATION OF ELECTRO-FENTON/-PERSULFATE PROCESSES FOLLOWING THE ACIDIFICATION FOR TSS REMOVAL FROM BIODIESEL WASTEWATER
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar