Yayın:
Accurate and sensitive determination of lead in black tea samples using cobalt magnetic particles based dispersive solid-phase microextraction prior to slotted quartz tube-flame atomic absorption spectrometry

dc.contributor.authorAkkaya, Erhan
dc.contributor.authorErulas, Fatih Ahmet
dc.contributor.authorBuyukpinar, Cagdas
dc.contributor.authorBakirdere, Sezgin
dc.date.accessioned2026-06-27T14:17:59Z
dc.date.issued2019
dc.description.abstractNewly developed combination of magnetic cobalt particles based dispersive solid-phase microextraction (Co-MP-DSPME) and slotted quartz tube attached flame atomic absorption spectrometry (SQT-FAAS) was utilized to determine lead at trace levels in tea samples. Co-MPs' adsorbent properties were tested and validated for their selectiveness to lead. Only with a few and short extraction steps (i.e. adding MPs, mixing, decanting and eluting) analyte was extracted from sample solution rapidly and efficiently. Limit of detection (LOD) and limit of quantification (LOQ) for the developed method (Co-MP-DSPME-SQT-FAAS) were found to be 7.77 mu g/L and 25.9 mu g/L, respectively. Matrix matching strategy was performed and outcomes indicated that the developed method is applicable with the high percent recovery values of 110.1 +/- 4.5 and % 102.9 +/- 4.2 for 100 and 300 mu g/kg lead standard spiked black tea samples, respectively. The method was also applied to standard reference material to check the accuracy of the method.en
dc.description.urihttps://doi.org/10.1016/j.foodchem.2019.06.014
dc.identifier.doi10.1016/j.foodchem.2019.06.014
dc.identifier.eissn1873-7072
dc.identifier.issn0308-8146
dc.identifier.pubmed31253290
dc.identifier.urihttps://hdl.handle.net/20.500.14981/58972
dc.identifier.volume297
dc.identifier.wos000473702200001
dc.language.isoeng
dc.publisherELSEVIER SCI LTD
dc.relation.ispartofFOOD CHEMISTRY
dc.subjectLead
dc.subjectDispersive solid-phase microextraction
dc.subjectCobalt magnetic particles
dc.subjectSlotted quartz tube
dc.subjectFlame atomic absorption spectroscopy
dc.subjectTea
dc.subjectOXIDE NANOPARTICLES
dc.subjectEXTRACTION
dc.subjectCADMIUM
dc.subjectWATER
dc.subjectPRECONCENTRATION
dc.subjectPB
dc.subjectCD
dc.subjectChemistry
dc.subjectFood Science & Technology
dc.subjectNutrition & Dietetics
dc.titleAccurate and sensitive determination of lead in black tea samples using cobalt magnetic particles based dispersive solid-phase microextraction prior to slotted quartz tube-flame atomic absorption spectrometry
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar