Yayın:
Determination of Manganese in Coffee and Wastewater Using Deep Eutectic Solvent Based Extraction and Flame Atomic Absorption Spectrometry

dc.contributor.authorTisli, Busra
dc.contributor.authorGosterisli, Tugce Unutkan
dc.contributor.authorZaman, Buse Tugba
dc.contributor.authorBakirdere, Emine Gulhan
dc.contributor.authorBakirdere, Sezgin
dc.date.accessioned2026-06-27T14:24:32Z
dc.date.issued2021
dc.description.abstractDeep eutectic solvent based liquid phase microextraction was utilized for the preconcentration of manganese in a simple and effective manner. In the developed analytical method, the extraction of manganese was carried out by using 3-[[(2-hydroxyphenyl)imino]methyl]-2-naphthalenol as the ligand, a choline chloride-phenol mixture as the extraction solvent, and tetrahydrofuran as the emulsifier agent. In order to achieve high detection power, all parameters affecting the extraction output such as the buffer (pH 10, 2.0 mL), ligand solution (0.02% (w/v), 1.50 mL), deep eutectic solvent (molar ratio (1:2), 500 mu L), tetrahydrofuran (1.0 mL) and instrumental parameters were optimized. Under the optimum conditions, the limit of detection, limit of quantitation, enrichment in detection power and relative standard deviation were determined to be 0.52 mu g L-1, 1.72 mu g L-1, 92.9-fold, and 2.7%, respectively. For the purpose of characterizing the accuracy in environmental and food samples, the method was successfully applied to wastewater and coffee samples, and the recovery results were shown to be satisfactory.en
dc.description.urihttps://doi.org/10.1080/00032719.2020.1789871
dc.identifier.doi10.1080/00032719.2020.1789871
dc.identifier.eissn1532-236X
dc.identifier.endpage989
dc.identifier.issn0003-2719
dc.identifier.issue6
dc.identifier.startpage979
dc.identifier.urihttps://hdl.handle.net/20.500.14981/60283
dc.identifier.volume54
dc.identifier.wos000547084500001
dc.language.isoeng
dc.publisherTAYLOR & FRANCIS INC
dc.relation.ispartofANALYTICAL LETTERS
dc.subjectDeep eutectic solvent
dc.subjectflame atomic absorption spectrometry
dc.subjectmanganese
dc.subjectmicroextraction
dc.subjectSOLID-PHASE EXTRACTION
dc.subjectCLOUD POINT EXTRACTION
dc.subjectSAMPLES
dc.subjectPRECONCENTRATION
dc.subjectNICKEL
dc.subjectCOPPER
dc.subjectIONS
dc.subjectZINC
dc.subjectPOTASSIUM
dc.subjectChemistry
dc.titleDetermination of Manganese in Coffee and Wastewater Using Deep Eutectic Solvent Based Extraction and Flame Atomic Absorption Spectrometry
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar