Yayın:
Simultaneous Analysis of Monovalent Anions and Cations with a Sub-Microliter Dead-Volume Flow-Through Potentiometric Detector for Ion Chromatography

dc.contributor.authorDumanli, Rukiye
dc.contributor.authorAttar, Azade
dc.contributor.authorErci, Vildan
dc.contributor.authorIsildak, Ibrahim
dc.date.accessioned2026-06-27T13:55:44Z
dc.date.issued2016
dc.description.abstractA microliter dead-volume flow-through cell as a potentiometric detector is described in this article for sensitive, selective and simultaneous detection of common monovalent anions and cations in single column ion chromatography for the first time. The detection cell consisted of less selective anion-and cation-selective composite membrane electrodes together with a solid-state composite matrix reference electrode. The simultaneous separation and sensitive detection of sodium (Na+), potassium (K+), ammonium (NH4+), chloride (Cl-) and nitrate (NO3-) in a single run was achieved by using 98% 1.5 mM MgSO4 and 2% acetonitrile eluent with a mixedbed ion-exchange separation column without suppressor column system. The separation and simultaneous detection of the anions and cations were completed in 6 min at the eluent flow-rate of 0.8 mL/min. Detection limits, at S/N = 3, were ranged from 0.2 to 1.0 mu M for the anions and 0.3 to 3.0 mu M for the cations, respectively. The developed method was successfully applied to the simultaneous determination of monovalent anions and cations in several environmental and biological samples.en
dc.description.urihttps://doi.org/10.1093/chromsci/bmv193
dc.identifier.doi10.1093/chromsci/bmv193
dc.identifier.eissn1945-239X
dc.identifier.endpage603
dc.identifier.issn0021-9665
dc.identifier.issue4
dc.identifier.pubmed26786906
dc.identifier.startpage598
dc.identifier.urihttps://hdl.handle.net/20.500.14981/55822
dc.identifier.volume54
dc.identifier.wos000380263900016
dc.language.isoeng
dc.publisherOXFORD UNIV PRESS INC
dc.relation.ispartofJOURNAL OF CHROMATOGRAPHIC SCIENCE
dc.rightsopenAccess
dc.subjectINORGANIC ANIONS
dc.subjectLIQUID-CHROMATOGRAPHY
dc.subjectORGANIC-ACIDS
dc.subjectEXCHANGE CHROMATOGRAPHY
dc.subjectCONDUCTIVITY DETECTION
dc.subjectWATER SAMPLES
dc.subjectCOLUMN
dc.subjectELECTRODE
dc.subjectNITRITE
dc.subjectDERIVATIZATION
dc.subjectBiochemistry & Molecular Biology
dc.subjectChemistry
dc.titleSimultaneous Analysis of Monovalent Anions and Cations with a Sub-Microliter Dead-Volume Flow-Through Potentiometric Detector for Ion Chromatography
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar