Yayın:
Surface roughness and wear behavior of occlusal splint materials made of contemporary and high-performance polymers

dc.contributor.authorBenli, Merve
dc.contributor.authorGumus, Beril Eker
dc.contributor.authorKahraman, Yusuf
dc.contributor.authorGokcen-Rohlig, Bilge
dc.contributor.authorEvlioglu, Gulumser
dc.contributor.authorHuck, Olivier
dc.contributor.authorOzcan, Mutlu
dc.date.accessioned2026-06-27T14:19:44Z
dc.date.issued2020
dc.description.abstractWith the development of a digital technology of computer-assisted manufacturing (CAD/CAM) and new age materials, the use of new types of occlusal splint is to consider. The aim of the present study was to evaluate the surface roughness (Ra) and wear behavior of different CAD/CAM materials against enamel antagonist through a simulated chewing test. A total of 75 specimens made from ethylene vinyl acetate (EVA), polymethyl methacrylate (PMMA), polycarbonate (PC), polyetheretherketone (PEEK), and polyethyleneterephthalate (PETG) as a control were polished to evaluate the Ra before loading by optical profilometry and further analyzed by scanning electron microscopy (SEM). Specimens of each group were subjected to thermomechanical fatigue loading in a chewing simulator (60000 cycles at 49 N with 5-55 degrees C thermocycling). The wear volume loss and change in Ra of each specimen after the simulated chewing were analyzed. One-way ANOVA, paired samples t test, and Pearson correlation analysis were performed for statistical analyzes. The result showed that the volume loss and Ra varied among the materials tested. EVA exhibited the greatest amount of Ra and volume loss (p 0.05). SEM investigations revealed different wear behaviors, especially in EVA. As PEEK showed significantly more favorable results, PEEK splints should be considered as a new therapeutic option for occlusal splint.en
dc.description.urihttps://doi.org/10.1007/s10266-019-00463-1
dc.identifier.doi10.1007/s10266-019-00463-1
dc.identifier.eissn1618-1255
dc.identifier.endpage250
dc.identifier.issn1618-1247
dc.identifier.issue2
dc.identifier.pubmed31612354
dc.identifier.startpage240
dc.identifier.urihttps://hdl.handle.net/20.500.14981/59318
dc.identifier.volume108
dc.identifier.wos000489919100001
dc.language.isoeng
dc.publisherSPRINGER
dc.relation.ispartofODONTOLOGY
dc.rightsopenAccess
dc.subjectOcclusal splint
dc.subjectPEEK
dc.subjectWear
dc.subjectSurface roughness
dc.subjectEVA
dc.subjectORAL APPLIANCES
dc.subjectIN-VITRO
dc.subjectCAD/CAM
dc.subjectFABRICATION
dc.subjectMANAGEMENT
dc.subjectPOLYETHERETHERKETONE
dc.subjectANTAGONIST
dc.subjectRESISTANCE
dc.subjectSTRENGTH
dc.subjectDESIGN
dc.subjectDentistry, Oral Surgery & Medicine
dc.titleSurface roughness and wear behavior of occlusal splint materials made of contemporary and high-performance polymers
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar