Yayın: A Novel all Solid-State Contact PVC-Membrane Beryllium-Selective Electrode Based on 4-Hydroxybenzo-15-Crown-5 Ether Ionophore
| dc.contributor.author | Isildak, Ibrahim | |
| dc.contributor.author | Attar, Azade | |
| dc.contributor.author | Demir, Ersin | |
| dc.contributor.author | Kemer, Baris | |
| dc.contributor.author | Aboul-Enein, Hassan Y. | |
| dc.date.accessioned | 2026-06-27T14:15:52Z | |
| dc.date.issued | 2018 | |
| dc.description.abstract | Aim: A novel all solid-state contact PVC-membrane beryllium-selective electrode based on 4-hydroxybenzo-15-crown-5 ether as an ionophore is described. Results: The best performance was obtained with a membrane composition of 4% ionophore, 67% dioctyl sebacate (DOS), 28% poly(vinyl chloride) (PVC), and 1% potassium tetrakis (p-chloro) phenylborate (KTClPB) (w/w). The all solid-state contact PVCmembrane beryllium-selective electrode together with an Ag/AgCl reference electrode exhibited sub-Nernstian response with a slope of 22 +/- 1 mV/decade to beryllium ions from 1.0x10(-6) to 1.0x10(-1) M, and resulted a considerably low detection limit of 6.2x10(-7). The electrode had a good performance in selectivity over a wide range of interfering cations tested. It showed a working pH range between 4.0-8.2 with fast response time (< 10 s) and a good reproducibility. Conclusion: The all solid-state contact PVC-membrane beryllium-selective electrode developed was successfully applied in potentiometric titration of Be2+ ions with EDTA. | en |
| dc.description.uri | https://doi.org/10.2174/1573411012666161014164546 | |
| dc.identifier.doi | 10.2174/1573411012666161014164546 | |
| dc.identifier.eissn | 1875-6727 | |
| dc.identifier.endpage | 48 | |
| dc.identifier.issn | 1573-4110 | |
| dc.identifier.issue | 1 | |
| dc.identifier.startpage | 43 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14981/58611 | |
| dc.identifier.volume | 14 | |
| dc.identifier.wos | 000419551200007 | |
| dc.language.iso | eng | |
| dc.publisher | BENTHAM SCIENCE PUBL LTD | |
| dc.relation.ispartof | CURRENT ANALYTICAL CHEMISTRY | |
| dc.subject | Beryllium-selective electrode | |
| dc.subject | 4-hydroxybenzo-15-crown-5 ether | |
| dc.subject | potentiometry | |
| dc.subject | PVC membrane | |
| dc.subject | ionophore | |
| dc.subject | EDTA | |
| dc.subject | ATOMIC-ABSORPTION-SPECTROMETRY | |
| dc.subject | ULTRA-TRACE BERYLLIUM | |
| dc.subject | POTENTIOMETRIC SENSOR | |
| dc.subject | DOUBLE HYDROXIDE | |
| dc.subject | WATER SAMPLES | |
| dc.subject | BE2+ ION | |
| dc.subject | EXTRACTION | |
| dc.subject | MAGNESIUM | |
| dc.subject | PLASMA | |
| dc.subject | SPECTROPHOTOMETRY | |
| dc.subject | Chemistry | |
| dc.title | A Novel all Solid-State Contact PVC-Membrane Beryllium-Selective Electrode Based on 4-Hydroxybenzo-15-Crown-5 Ether Ionophore | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| local.import.source | WOS |