Yayın:
Dispersive solid phase extraction and quadruple isotope dilution-mass spectrometry combination for the accurate and sensitive quantification of capsaicin in pepper, domestic wastewater and human saliva samples by GC-MS system

dc.contributor.authorBodur, Suleyman
dc.contributor.authorBodur, Sezin Erarpat
dc.contributor.authorGursoy, Selim
dc.contributor.authorAyyildiz, Merve Firat
dc.contributor.authorKartoglu, Bedrihan
dc.contributor.authorAkbiyik, Hilal
dc.contributor.authorGunkara, Omer Tahir
dc.contributor.authorBakirdere, Sezgin
dc.date.accessioned2026-06-27T15:01:53Z
dc.date.issued2025
dc.description.abstractIn the presented study, reduced graphene oxide/Fe3O4 (rGO/Fe3O4) nanocomposites based dispersive solid phase extraction (DSPE) - gas chromatography-mass spectrometry (GC-MS) method was developed for the determination of capsaicin in domestic wastewater (DW), pepper (PP) and human saliva (HS) samples. All important parameters of the DSPE method affected the preconcentration factor were carefully optimized to achieve high signal to noise ratio for the analyte. After the optimization studies, the system analytical performance of DSPEGC-MS system was evaluated using the aqueous standard solution of capsaicin. Limit of detection (LOD), limit of quantitation (LOQ) and dynamic range were figured out to be 0.54 mu g/kg, 1.80 mu g/kg and 2.66 - 487.35 mu g/kg, respectively. Under the optimum experimental conditions, recovery studies were conducted with the spiked DW, PP and HS samples, and percent recovery results were recorded between 52.6 % and 183.6 % via matrix matching calibration strategy. After the implementation of ID4 strategy, percent recovery results for the spiked DW, PP and HS samples were calculated as 98.2 %-99.3 %, 99.7 %-100.7 % and 99.4 %-99.8 %, respectively. In addition, capsaicin content in Sivri (S)-PP, Kil (K)-PP and Samandag (SA)-PP samples were found to be 309.5 +/- 11.8 mg/kg, 873.7 +/- 26.7 mg/kg and 165.3 +/- 5.1 mg/kg via DSPE-GC-ID4-MS method, respectively. As a result, the combination of quadruple isotope dilution (ID4) strategy and the DSPE-GC-MS method were successfully performed to boost the accuracy and precision of developed DSPE-GC-MS method.en
dc.description.sponsorshipScientific and Technological Research Council of Turkey (TUBITAK) [122Z041]
dc.description.urihttps://doi.org/10.1016/j.microc.2024.112246
dc.identifier.doi10.1016/j.microc.2024.112246
dc.identifier.eissn1095-9149
dc.identifier.issn0026-265X
dc.identifier.urihttps://hdl.handle.net/20.500.14981/67363
dc.identifier.volume208
dc.identifier.wos001370602800001
dc.language.isoeng
dc.publisherELSEVIER
dc.relation.ispartofMICROCHEMICAL JOURNAL
dc.subjectCapsaicin
dc.subjectDispersive solid phase extraction
dc.subjectDomestic wastewater
dc.subjectPepper
dc.subjectQuadruple isotope dilution
dc.subjectDIHYDROCAPSAICIN
dc.subjectNANOPARTICLES
dc.subjectSEAWATER
dc.subjectChemistry
dc.titleDispersive solid phase extraction and quadruple isotope dilution-mass spectrometry combination for the accurate and sensitive quantification of capsaicin in pepper, domestic wastewater and human saliva samples by GC-MS system
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar