Yayın:
Biomechanical comparison of straight DCP and helical plates for fixation of transverse and oblique bone fractures

dc.contributor.authorAksakal, Bunyamin
dc.contributor.authorGurger, Murat
dc.contributor.authorSay, Yakup
dc.contributor.authorYilmaz, Erhan
dc.date.accessioned2026-06-27T13:37:46Z
dc.date.issued2014
dc.description.abstractPurpose: Biomechanical comparison of straight DCP and helical plates for fixation of transversal and oblique tibial bone fractures were analyzed and compared to each other by axial compression, bending and torsion tests. Method: An in vitro osteosynthesis of transverse (TF) and oblique bone fracture (OF) fixations have been analysed on fresh sheep tibias by using the DCP and helical compression plates (HP). Results: Statistically significant differences were found for both DCP and helical plate fixations under axial compression, bending and torsional loads. The strength of fixation systems was in favor of DC plating with exception of the TF-HP fixation group under compression loads and torsional moments. The transvers fracture (TF) stability was found to be higher than that found in oblique fracture (OF) fixed by helical plates (HP). However, under torsional testing, compared to conventional plating, the helical plate fixations provided a higher torsional resistance and strength. The maximum stiffness at axial compression loading and maximum torsional strength was achieved in torsional testing for the TF-HP fixations. Conclusion: From in vitro biomechanical analysis, fracture type and plate fixation system groups showed different responses under different loadings. Consequently, current biomechanical analyses may encourage the usage of helical HP fixations in near future during clinical practice for transverse bone fractures.en
dc.description.urihttps://doi.org/10.5277/abb-00045-2014-01
dc.identifier.doi10.5277/abb-00045-2014-01
dc.identifier.endpage74
dc.identifier.issn1509-409X
dc.identifier.issue4
dc.identifier.pubmed25597271
dc.identifier.startpage67
dc.identifier.urihttps://hdl.handle.net/20.500.14981/53922
dc.identifier.volume16
dc.identifier.wos000348507400008
dc.language.isoeng
dc.publisherWROCLAW UNIV TECHNOLOGY
dc.relation.ispartofACTA OF BIOENGINEERING AND BIOMECHANICS
dc.subjectstraight DC plate
dc.subjecthelical plate
dc.subjectbiomechanics
dc.subjectfixation
dc.subjectbone fractures
dc.subjectTIBIAL FRACTURES
dc.subjectMICROMOVEMENT
dc.subjectHUMERUS
dc.subjectBiophysics
dc.subjectEngineering
dc.titleBiomechanical comparison of straight DCP and helical plates for fixation of transverse and oblique bone fractures
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar