Yayın:
Electrochemical Determination of Copper(II) in Water Samples Using a Novel Ion-Selective Electrode Based on a Graphite Oxide-Imprinted Polymer Composite

dc.contributor.authorTopcu, Cihan
dc.contributor.authorLacin, Gamze
dc.contributor.authorYilmaz, Vedat
dc.contributor.authorColdur, Fatih
dc.contributor.authorCaglar, Bulent
dc.contributor.authorCubuk, Osman
dc.contributor.authorIsildak, Ibrahim
dc.date.accessioned2026-06-27T14:12:17Z
dc.date.issued2018
dc.description.abstractA novel copper(II)-selective electrode based on graphite oxide/imprinted polymer composite was developed for the electrochemical monitoring of copper(II) (Cu2+) ions. The electrode exhibited highly selective potentiometric response to Cu2+ with respect to common alkaline, alkaline earth and heavy metal cations. The composite composition studies indicated that the most suitable composite composition performing the most promising potentiometric properties was 20.0% ionophore (Cu2+-ion imprinted polymer), 10.0% paraffin oil, 5.0% multiwalled carbon nanotubes, and 65.0% graphite oxide. The fabricated electrode exhibited a linear response to Cu2+ over the concentration range of 1.0 x 10(-6)-1.0 x 10(-1) M (correlation coefficient of 0.9998) with a sensitivity of 26.1 +/- 0.9 mV decade(-1). The detection limit of the fabricated electrode was determined to be 4.0 x 10(-7) M. The electrode worked well in the pH range of 4.0-8.0. The electrode had stable, reversible and fast potentiometric response (3 s). In addition, the electrode had a lifetime of more than 1 year. The analytical applications of the proposed electrode were performed using as an indicator electrode for the potentiometric titration of Cu2+ with ethylene diamine tetraacetic acid solution and for the determination of Cu2+ of spiked river, dam, and tap water samples. The obtained results for potentiometric titration and water samples were satisfactory.en
dc.description.urihttps://doi.org/10.1080/00032719.2017.1395035
dc.identifier.doi10.1080/00032719.2017.1395035
dc.identifier.eissn1532-236X
dc.identifier.endpage1910
dc.identifier.issn0003-2719
dc.identifier.issue12
dc.identifier.startpage1890
dc.identifier.urihttps://hdl.handle.net/20.500.14981/57916
dc.identifier.volume51
dc.identifier.wos000430986500006
dc.language.isoeng
dc.publisherTAYLOR & FRANCIS INC
dc.relation.ispartofANALYTICAL LETTERS
dc.subjectCopper(II) determination
dc.subjectcopper(II)-selective electrode
dc.subjection-imprinted polymer
dc.subjectpotentiometry
dc.subjectwater analysis
dc.subjectSYNTHESIZED SCHIFF-BASE
dc.subjectSPECTROPHOTOMETRIC DETERMINATION
dc.subjectPOTENTIOMETRIC SENSOR
dc.subjectMERCURY IONS
dc.subjectMEMBRANE
dc.subjectIONOPHORE
dc.subjectZINC
dc.subjectMANGANESE
dc.subjectMATRICES
dc.subjectChemistry
dc.titleElectrochemical Determination of Copper(II) in Water Samples Using a Novel Ion-Selective Electrode Based on a Graphite Oxide-Imprinted Polymer Composite
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar