Yayın: Electrochemical Determination of Copper(II) in Water Samples Using a Novel Ion-Selective Electrode Based on a Graphite Oxide-Imprinted Polymer Composite
| dc.contributor.author | Topcu, Cihan | |
| dc.contributor.author | Lacin, Gamze | |
| dc.contributor.author | Yilmaz, Vedat | |
| dc.contributor.author | Coldur, Fatih | |
| dc.contributor.author | Caglar, Bulent | |
| dc.contributor.author | Cubuk, Osman | |
| dc.contributor.author | Isildak, Ibrahim | |
| dc.date.accessioned | 2026-06-27T14:12:17Z | |
| dc.date.issued | 2018 | |
| dc.description.abstract | A novel copper(II)-selective electrode based on graphite oxide/imprinted polymer composite was developed for the electrochemical monitoring of copper(II) (Cu2+) ions. The electrode exhibited highly selective potentiometric response to Cu2+ with respect to common alkaline, alkaline earth and heavy metal cations. The composite composition studies indicated that the most suitable composite composition performing the most promising potentiometric properties was 20.0% ionophore (Cu2+-ion imprinted polymer), 10.0% paraffin oil, 5.0% multiwalled carbon nanotubes, and 65.0% graphite oxide. The fabricated electrode exhibited a linear response to Cu2+ over the concentration range of 1.0 x 10(-6)-1.0 x 10(-1) M (correlation coefficient of 0.9998) with a sensitivity of 26.1 +/- 0.9 mV decade(-1). The detection limit of the fabricated electrode was determined to be 4.0 x 10(-7) M. The electrode worked well in the pH range of 4.0-8.0. The electrode had stable, reversible and fast potentiometric response (3 s). In addition, the electrode had a lifetime of more than 1 year. The analytical applications of the proposed electrode were performed using as an indicator electrode for the potentiometric titration of Cu2+ with ethylene diamine tetraacetic acid solution and for the determination of Cu2+ of spiked river, dam, and tap water samples. The obtained results for potentiometric titration and water samples were satisfactory. | en |
| dc.description.uri | https://doi.org/10.1080/00032719.2017.1395035 | |
| dc.identifier.doi | 10.1080/00032719.2017.1395035 | |
| dc.identifier.eissn | 1532-236X | |
| dc.identifier.endpage | 1910 | |
| dc.identifier.issn | 0003-2719 | |
| dc.identifier.issue | 12 | |
| dc.identifier.startpage | 1890 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14981/57916 | |
| dc.identifier.volume | 51 | |
| dc.identifier.wos | 000430986500006 | |
| dc.language.iso | eng | |
| dc.publisher | TAYLOR & FRANCIS INC | |
| dc.relation.ispartof | ANALYTICAL LETTERS | |
| dc.subject | Copper(II) determination | |
| dc.subject | copper(II)-selective electrode | |
| dc.subject | ion-imprinted polymer | |
| dc.subject | potentiometry | |
| dc.subject | water analysis | |
| dc.subject | SYNTHESIZED SCHIFF-BASE | |
| dc.subject | SPECTROPHOTOMETRIC DETERMINATION | |
| dc.subject | POTENTIOMETRIC SENSOR | |
| dc.subject | MERCURY IONS | |
| dc.subject | MEMBRANE | |
| dc.subject | IONOPHORE | |
| dc.subject | ZINC | |
| dc.subject | MANGANESE | |
| dc.subject | MATRICES | |
| dc.subject | Chemistry | |
| dc.title | Electrochemical Determination of Copper(II) in Water Samples Using a Novel Ion-Selective Electrode Based on a Graphite Oxide-Imprinted Polymer Composite | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| local.import.source | WOS |