Yayın:
Sensitive determination of cadmium in lake water, municipal wastewater and onion samples by slotted quartz tube-flame atomic absorption spectrometry after preconcentration with microextraction strategy

dc.contributor.authorKafa, Emine Betul
dc.contributor.authorFirat, Merve
dc.contributor.authorChormey, Dotse Selali
dc.contributor.authorTurak, Fatma
dc.contributor.authorBakirdere, Sezgin
dc.date.accessioned2026-06-27T14:13:17Z
dc.date.issued2018
dc.description.abstractThis study presents the coupling of slotted quartz tube with flame atomic absorption spectrometry for the determination of cadmium after preconcentration with dispersive liquid-liquid microextraction. A bipyridine ligand was used to form covalent cadmium complex, and the formation yield was increased by optimizing parameters such as pH/amount of buffer solution and ligand concentration. Parameters that influence the extraction output and slotted quartz tube efficiency were also optimized to increase the sensitivity. The optimization steps added up to give about 135 times increased sensitivity in comparison to the conventional flame atomic absorption spectrometry. The limits of detection and quantification obtained under optimum experimental conditions were 0.31 and 1.04 mu g L-1, respectively. Applicability of the method was tested on lake water, municipal wastewater and onion samples spiked at different concentrations. Percentage recoveries were found to be between 84 and 105% for the samples, and matrix matching was used to obtain 98.6% recovery for onion spiked at 20 mu g L-1.en
dc.description.urihttps://doi.org/10.1016/j.measurement.2018.04.068
dc.identifier.doi10.1016/j.measurement.2018.04.068
dc.identifier.eissn1873-412X
dc.identifier.endpage223
dc.identifier.issn0263-2241
dc.identifier.startpage219
dc.identifier.urihttps://hdl.handle.net/20.500.14981/58098
dc.identifier.volume125
dc.identifier.wos000436642500024
dc.language.isoeng
dc.publisherELSEVIER SCI LTD
dc.relation.ispartofMEASUREMENT
dc.subjectCadmium
dc.subjectDLLME
dc.subjectSQT
dc.subjectFAAS
dc.subjectLIQUID-LIQUID MICROEXTRACTION
dc.subjectCARBON-PASTE ELECTRODE
dc.subjectBIOLOGICAL SAMPLES
dc.subjectTRACE AMOUNT
dc.subjectICP-MS
dc.subjectEXTRACTION
dc.subjectLEAD
dc.subjectINTERFERENCE
dc.subjectVOLTAMMETRY
dc.subjectGENERATION
dc.subjectEngineering
dc.subjectInstruments & Instrumentation
dc.titleSensitive determination of cadmium in lake water, municipal wastewater and onion samples by slotted quartz tube-flame atomic absorption spectrometry after preconcentration with microextraction strategy
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar