Yayın:
Spray assisted preconcentration method combined with HPLC-Continuous flow hydride generation-FAAS for inorganic arsenic speciation in olive oil samples

dc.contributor.authorBodur, Sueleyman
dc.contributor.authorErarpat, Sezin
dc.contributor.authorTutar, Omer Faruk
dc.contributor.authorBakirdere, Sezgin
dc.date.accessioned2026-06-27T14:55:54Z
dc.date.issued2023
dc.description.abstractSpeciation analysis of arsenic in edible oils is an important topic in terms of the assessment of its risks for human health and the quality of edible oils. In this study, high performance liquid chromatography - continuous flow hydride generation - flame atomic absorption spectrometry (HPLC-CFHG-FAAS) system after vortex assisted reverse phase spray-based fine droplet formation liquid phase microextraction (VA-RP-SFDF-LPME) method was proposed to qualify/quantify arsenite and total arsenic. Limit of detection (LOD) and limit of quantification (LOQ) for arsenite were calculated as 2.86 & mu;g kg-1 (as As) and 9.52 & mu;g kg-1 (as As), respectively. After the extraction/preconcentration process, a prereduction was carried out in the presence of 0.010 mol/L HCl (con-taining 0.39% L-cysteine) with heat (90 & PLUSMN; 5 oC) for the determination of total arsenic content while arsenite was directly determined via the developed system. Recovery for arsenite and total inorganic arsenic were in the range of 91.5 - 120.4% and 90.0 - 104.4%, respectively. The developed method is proposed for the analysis of olive oil samples containing inorganic arsenic species. This is the first study to carry out the inorganic arsenic speciation in olive oil by HPLC-CFHG-FAAS system after the preconcentration of the species by the VA-RP-SFDF-LPME system. For the matrix including arsenite and arsenate, the developed method can be safely used to find the concentration of both species accurately.en
dc.description.urihttps://doi.org/10.1016/j.jfca.2023.105531
dc.identifier.doi10.1016/j.jfca.2023.105531
dc.identifier.eissn1096-0481
dc.identifier.issn0889-1575
dc.identifier.urihttps://hdl.handle.net/20.500.14981/66370
dc.identifier.volume123
dc.identifier.wos001050777400001
dc.language.isoeng
dc.publisherACADEMIC PRESS INC ELSEVIER SCIENCE
dc.relation.ispartofJOURNAL OF FOOD COMPOSITION AND ANALYSIS
dc.subjectInorganic arsenic speciation
dc.subjectFAAS
dc.subjectHydride generation
dc.subjectMicroextraction
dc.subjectATOMIC-ABSORPTION-SPECTROMETRY
dc.subjectLIQUID-LIQUID MICROEXTRACTION
dc.subjectRESPONSE-SURFACE METHODOLOGY
dc.subjectBOX-BEHNKEN DESIGN
dc.subjectEDIBLE OILS
dc.subjectONLINE PRECONCENTRATION
dc.subjectEXTRACTION METHODS
dc.subjectWATER SAMPLES
dc.subjectWEST-BENGAL
dc.subjectL-CYSTEINE
dc.subjectChemistry
dc.subjectFood Science & Technology
dc.titleSpray assisted preconcentration method combined with HPLC-Continuous flow hydride generation-FAAS for inorganic arsenic speciation in olive oil samples
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar