Experimental evaluation of performance parameters of a domestic freezer under door opening conditions

dc.contributor.authorIpek, Mutlu
dc.contributor.authorDincer, Ibrahim
dc.date.accessioned2026-06-27T15:10:27Z
dc.date.issued2024
dc.description.abstractThe current study focuses on a comprehensive experimental assessment of the cooling system parameters of a domestic-type upright freezer that is equipped with shelves and test packages under periodic door opening conditions, referring to real user scenarios. The influence of varying ambient relative humidity levels as well as the load state of the cabinet are taken into account. The study reveals that both heat and moisture have a crucial effect on the average air temperature inside the cabinet, the temperature of the walls, the transient evaporation and condensation pressure behaviour of the refrigerant, as well as the compressor power, the total operation ratio of the compressor, and the overall amount of energy consumption. The specific performance experiments are conducted at 32 degrees C ambient and 35 %, 65 %, and 85 % relative humidity conditions with unloaded, halfloaded, and full-loaded cases. The obtained data and results are evaluated between frosting, influenced by altering ambient humidity levels, and cabinet load state under periodic door openings where the variation in energy consumption is clearly measured. Consequently, the amounts of frost accumulation in the cabinet under half and full loaded conditions at 32 degrees C an 85 % relative humidity conditions are observed to be about 220 g and 270 g, respectively, followed by regular door openings and closings which result in a raise in total energy consumption rate of 7.6 % and 11.2 % compared to the period before the door opening. The frost accumulation in the full loaded condition at 32 degrees C and 85 % RH is found to be 2.4 times greater than the unloaded condition with a relative humidity (RH) of 35 % whereas the energy consumption is 3.7 times higher.en
dc.description.sponsorshipArcelik Global
dc.description.urihttps://doi.org/10.1016/j.tsep.2024.102665
dc.identifier.doi10.1016/j.tsep.2024.102665
dc.identifier.issn2451-9049
dc.identifier.urihttps://hdl.handle.net/20.500.14981/68574
dc.identifier.volume52
dc.identifier.wos001249218000001
dc.language.isoeng
dc.publisherELSEVIER
dc.relation.ispartofTHERMAL SCIENCE AND ENGINEERING PROGRESS
dc.subjectRefrigeration
dc.subjectUpright Freezer
dc.subjectHumid Air
dc.subjectPeriodic Door Opening
dc.subjectEnergy Consumption
dc.subjectSystem Parameters
dc.subjectREFRIGERATOR
dc.subjectENERGY
dc.subjectTEMPERATURE
dc.subjectSIMULATION
dc.subjectThermodynamics
dc.subjectEnergy & Fuels
dc.subjectEngineering
dc.subjectMechanics
dc.titleExperimental evaluation of performance parameters of a domestic freezer under door opening conditions