Yayın:
Simultaneous, Selective and Highly Sensitive Voltammetric Determination of Lead, Cadmium, and Zinc via Modified Pencil Graphite Electrodes

dc.contributor.authorUstabasi, Gul Sirin
dc.contributor.authorYilmaz, Ismail
dc.contributor.authorOzcan, Mustafa
dc.contributor.authorCetinkaya, Ebru
dc.date.accessioned2026-06-27T14:45:56Z
dc.date.issued2022
dc.description.abstractPencil graphite electrode (PGE) modified with MWCNT and Bi3+ (MWCNT/Bi/PGE) was utilized in simultaneous analysis of Pb2+, Cd2+, and Zn2+. Surface and electrochemical characteristics of MWCNT/Bi/PGE were investigated via SEM, cyclic voltammetry, electrochemical impedance spectroscopy, and FTIR measurements. Even though modification with MWCNT did not improve the electroactive surface area, it significantly decreased the charge transfer resistance. Furthermore, modification with Bi3+ significantly increased the sensitivity. Finally, MWCNT/Bi/PGE exhibited the highest sensitivity and reproducibility compared to PGE and PGE modified with only MWCNT. MWCNT/Bi/PGE provided LOD values of 0.27, 0.43, and 1.63 mu g L-1, and linear ranges of 1-80, 5-80, and 10-80 mu g L-1 for Pb2+, Cd2+, and Zn2+, respectively. Proposed modification method offers effective electroanalytical performance with low time consumption and cost for the analyst.en
dc.description.sponsorshipScientific and Technological Research Council of Turkey (TUBITAK)
dc.description.sponsorshipMir Research and Development in the frame of 2244-Industrial PhD Fellowship Program [118C108]
dc.description.urihttps://doi.org/10.1002/elan.202100512
dc.identifier.doi10.1002/elan.202100512
dc.identifier.eissn1521-4109
dc.identifier.endpage1244
dc.identifier.issn1040-0397
dc.identifier.issue8
dc.identifier.startpage1237
dc.identifier.urihttps://hdl.handle.net/20.500.14981/64483
dc.identifier.volume34
dc.identifier.wos000746012200001
dc.language.isoeng
dc.publisherWILEY-V C H VERLAG GMBH
dc.relation.ispartofELECTROANALYSIS
dc.subjectHeavy metals
dc.subjectpencil graphite electrode
dc.subjectsquare wave anodic stripping voltammetry
dc.subjectBISMUTH-FILM ELECTRODES
dc.subjectSTRIPPING VOLTAMMETRY
dc.subjectCARBON
dc.subjectCOMPOSITE
dc.subjectSAMPLES
dc.subjectPB
dc.subjectSTRATEGIES
dc.subjectMETALS
dc.subjectCD(II)
dc.subjectPB(II)
dc.subjectChemistry
dc.subjectElectrochemistry
dc.titleSimultaneous, Selective and Highly Sensitive Voltammetric Determination of Lead, Cadmium, and Zinc via Modified Pencil Graphite Electrodes
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar