Yayın:
Importance of Measurement Parameters for the Dental Implant Surface Characterization

dc.contributor.authorGunay, A.
dc.contributor.authorSagbas, B.
dc.contributor.authorDurakbasa, M. N.
dc.contributor.institutionauthorSAĞBAŞ, Binnur
dc.date.accessioned2026-06-27T13:30:15Z
dc.date.issued2014
dc.description.abstractPure titanium and its alloys have been widely used in biomedical applications on account of their biological and mechanical properties. Although the mechanical properties of titanium provide acceptable responses under dynamic pressures, surface modifications are needed in order to improve osseointegration between bone-implant interfaces. There are many different surface modification techniques like sand blasting, acid etching, or coating with various materials. Surface characterization is as important as surface modification for dental implants. Although many researchers studied about measurement of surface characteristics of dental implants with similar techniques but with different measurement parameters, there is still no consensus about the optimal surface characteristics values of a successful dental implant. Among many other surface characteristics, surface roughness is one of the most important features for dental implants. In this study, the importance of surface roughness measurement of dental implants is discussed and the need of a standardized procedure for implant surface roughness measurement is emphasized. In our experimental study three different processed surfaces as sand blasted and hydrofluoric acid etched surfaces, sand blasted and nitric acid etched surfaces and blasted surfaces were investigated. Results are compared via each method and each processing technique. It is aimed to highlight the importance of a standardized method for measuring and describing surface characteristics. More definitive, standardized methods are needed to augment the rather existing varied combined measurement parameters which affect the results for the assessment of biomedical surfaces.en
dc.description.urihttps://doi.org/10.12693/aphyspola.125.484
dc.identifier.doi10.12693/aphyspola.125.484
dc.identifier.eissn1898-794X
dc.identifier.endpage487
dc.identifier.issn0587-4246
dc.identifier.issue2
dc.identifier.startpage484
dc.identifier.urihttps://hdl.handle.net/20.500.14981/53298
dc.identifier.volume125
dc.identifier.wos000339825400103
dc.language.isoeng
dc.publisherPOLISH ACAD SCIENCES INST PHYSICS
dc.relation.conference3rd International Congress on Advances in Applied Physics and Materials Science
dc.relation.ispartofACTA PHYSICA POLONICA A
dc.rightsopenAccess
dc.subjectROUGHNESS
dc.subjectTITANIUM
dc.subjectWETTABILITY
dc.subjectPhysics
dc.titleImportance of Measurement Parameters for the Dental Implant Surface Characterization
dc.typeArticle; Proceedings Paper
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar