Yayın:
An experimental case study on the effect of condenser geometry in a refrigerator: Sub-cooling and coefficient of performance issues

dc.contributor.authorBorikar, Sanjaykumar A.
dc.contributor.authorBorikar, Dilipkumar A.
dc.contributor.authorPanchal, Hitesh
dc.contributor.authorCuce, Erdem
dc.contributor.authorDalkilic, Ahmet Selim
dc.contributor.authorAlrubaie, Ali Jawad
dc.contributor.authorJaber, Mustafa Musa
dc.date.accessioned2026-06-27T14:51:12Z
dc.date.issued2023
dc.description.abstractThe study aims to establish the role of the condenser and condenser geometry in the performance enhancement of the future generation of mid-sized refrigerators. Experimental and statistical methods were used to examine the influence and significance of ambient temperature, condenser geometry, and heat load on refrigerator per-formance. Experimentation was conducted on the experimental facility under standard designated operating conditions (i.e., 32 degrees C ambient temperature and 5 degrees C fresh food temperature). The experimental evaluations of refrigerators represent increase 13% - 29% in the coefficient of performance and 24% in the sub-cooling for improved factor fixation during the experiment. The analysis of variance comments upon the most influencing input factor that affects the performance most. Experimentally and analytically the combination of ambient temperature and the condenser geometry produces an impact on coefficient of performance and sub-cooling than other combinations. The analysis of variance determined the correct fit of the second-order quadratic model with a root mean square value of 0.994 and a root mean square value adjusted of 0.954.en
dc.description.urihttps://doi.org/10.1016/j.ijrefrig.2023.01.002
dc.identifier.doi10.1016/j.ijrefrig.2023.01.002
dc.identifier.eissn1879-2081
dc.identifier.endpage82
dc.identifier.issn0140-7007
dc.identifier.startpage75
dc.identifier.urihttps://hdl.handle.net/20.500.14981/65565
dc.identifier.volume148
dc.identifier.wos000972699300001
dc.language.isoeng
dc.publisherELSEVIER SCI LTD
dc.relation.ispartofINTERNATIONAL JOURNAL OF REFRIGERATION
dc.subjectCondenser geometry
dc.subjectCoefficient of performance
dc.subjectSub-cooling
dc.subjectAnalysis of variance
dc.subjectFactorial design
dc.subjectThermodynamics
dc.subjectEngineering
dc.titleAn experimental case study on the effect of condenser geometry in a refrigerator: Sub-cooling and coefficient of performance issues