Yayın:
A very sensitive flow-injection spectrophotometric determination method for iron (II) and total iron using 2′, 3, 4′, 5, 7-pentahydroxyflavone

dc.contributor.authorAsan, Adem
dc.contributor.authorAydin, Rukiye
dc.contributor.authorSemiz, Deniz Karsli
dc.contributor.authorErci, Vildan
dc.contributor.authorIsildak, Ibrahim
dc.date.accessioned2026-06-27T13:23:27Z
dc.date.issued2013
dc.description.abstractIn this study, an ultra-sensitive and highly selective, rapid flow-injection spectrophotometric method for the determination of iron (II) and total iron has been proposed. The method was based on the reaction between iron (II) and 2', 3, 4', 5, 7-pentahydroxyflavone in slightly acidic solution with a strong absorption at 415 nm. The carrier solution used was 1 x 10(-5) M 2', 3, 4', 5, 7-pentahydroxyflavone in 0.1 M HAc/Ac- buffer solution at pH 4.5. Parameters that affect simultaneously the determination of iron (II) and interfering ions were tested. The relative standard deviation for the determination of 50 mu g L-1 iron (II) was 0.85 % (n = 10), and the limit of detection (blank signal plus three times the standard deviation of the blank) was 3 mu g L-1, both based on injection volumes of 20 mu L. The method has been successfully applied to the determination of iron (II) and total iron in water samples and ore samples. The method was verified by analysing a certified reference material Zn/Al/Cu 43XZ3F.en
dc.description.urihttps://doi.org/10.1007/s10661-012-2693-y
dc.identifier.doi10.1007/s10661-012-2693-y
dc.identifier.eissn1573-2959
dc.identifier.endpage2121
dc.identifier.issn0167-6369
dc.identifier.issue3
dc.identifier.pubmed22628104
dc.identifier.startpage2115
dc.identifier.urihttps://hdl.handle.net/20.500.14981/52537
dc.identifier.volume185
dc.identifier.wos000314033300006
dc.language.isoeng
dc.publisherSPRINGER
dc.relation.ispartofENVIRONMENTAL MONITORING AND ASSESSMENT
dc.subjectFlow-injection analysis
dc.subjectIron
dc.subjectSpectrophotometry
dc.subject2 ', 3, 4 ', 5, 7-Pentahydroxyflavone
dc.subjectWATER SAMPLES
dc.subjectIRON(III)
dc.subjectACID
dc.subjectFE(III)
dc.subjectPRECONCENTRATION
dc.subjectSPECIATION
dc.subjectFERROZINE
dc.subjectSEAWATER
dc.subjectRESIN
dc.subjectEnvironmental Sciences & Ecology
dc.titleA very sensitive flow-injection spectrophotometric determination method for iron (II) and total iron using 2′, 3, 4′, 5, 7-pentahydroxyflavone
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar