Yayın:
Practical simulation method for determination of effective atomic number from Rayleigh to Compton scattering ratio by MCNP

dc.contributor.authorToker, Ozan
dc.contributor.authorBilmez, Bayram
dc.contributor.authorAkcali, Ozgur
dc.contributor.authorToker, Melis Ozsahin
dc.contributor.authorIcelli, Orhan
dc.date.accessioned2026-06-27T14:34:09Z
dc.date.issued2021
dc.description.abstractMonte Carlo simulation of the Rayleigh/Compton scattering method for effective atomic number determination with MCNP (version 6.2) was proposed. As known, effective atomic numbers can be used for evaluating shielding behavior, in non-destructive analysis and medical imaging, especially for binary compounds with high precision. Various methods for the determination of effective atomic number are present in the literature, and they depend on different mathematical manipulations. For the first time, a simulation method was developed for the determination of effective atomic numbers of some compounds. Rayleigh to Compton scattering intensity ratios (R/C) of seven different pure elements (from Indium to Gadolinium) were determined with simulations. A straight line equation is fitted using R/C scattering intensity ratios of these seven elements. R/C values of five different compounds were also simulated. Thus, effective atomic numbers of these compounds were determined using the equation. The results of the simulation were compared with available experimental and theoretical results. The studied simulation method showed acceptable agreement with ZXCOM calculation results and acceptable results with the experimental study. This method is suitable to be used for almost every material type and quite insensitive to experimental details, such as material phase, thickness, etc. The simulation results are really encouraging and can be used to guide various experiments.en
dc.description.urihttps://doi.org/10.1016/j.radphyschem.2020.109330
dc.identifier.doi10.1016/j.radphyschem.2020.109330
dc.identifier.eissn1879-0895
dc.identifier.issn0969-806X
dc.identifier.urihttps://hdl.handle.net/20.500.14981/62177
dc.identifier.volume181
dc.identifier.wos000618758200003
dc.language.isoeng
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD
dc.relation.ispartofRADIATION PHYSICS AND CHEMISTRY
dc.subjectRayleigh to compton
dc.subjectEffective atomic number
dc.subjectSimulation
dc.subjectZXCOM
dc.subjectMCNP 6.2
dc.subjectChemistry
dc.subjectNuclear Science & Technology
dc.subjectPhysics
dc.titlePractical simulation method for determination of effective atomic number from Rayleigh to Compton scattering ratio by MCNP