Yayın:
Fabrication of Tetra-Substituted Copper(II) Phthalocyanine-Graphene Modified Pencil Graphite Electrode for Amperometric Detection of Hydrogen Peroxide

dc.contributor.authorGorduk, Ozge
dc.contributor.authorGorduk, Semih
dc.contributor.authorSahin, Yucel
dc.date.accessioned2026-06-27T14:24:05Z
dc.date.issued2020
dc.description.abstractIn this study, tetra-substituted copper(II) phthalocyanine-graphene modified pencil graphite electrode (CuPc-Gr/PGE) was developed for the amperometric determination of hydrogen peroxide (H2O2) for the first time in the literature. The developed non-enzymatic electrode platform was electrochemically characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) methods. Scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS) methods were also used for surface characterization of the modified electrode. The response to H(2)O(2)at the working potential of -0.4 V is linear in the 0.1 mu M to 100 mu M concentration range in PBS pH 7.0. The limit of detection (LOD) and limit of quantitation (LOQ) are 0.045 and 0.15 mu M, respectively. Good selectivity was observed within physiological interference species such as ascorbic acid, dopamine, uric acid, and glucose. Additionally, amount of H(2)O(2)was determined using the novel produced non-enzymatic sensor with satisfactory results in beverage samples. These consequences imply that the CuPc-Gr/PGE displays effective electrocatalytic activity for the reduction of H2O2, indicating it has capability use for the detection of H2O2.en
dc.description.sponsorshipScientific Research Projects Coordination of Yildiz Technical University [FBA-2019-3764]
dc.description.urihttps://doi.org/10.1149/2162-8777/ab9c7a
dc.identifier.doi10.1149/2162-8777/ab9c7a
dc.identifier.eissn2162-8777
dc.identifier.issn2162-8769
dc.identifier.issue6
dc.identifier.urihttps://hdl.handle.net/20.500.14981/60194
dc.identifier.volume9
dc.identifier.wos000549801700001
dc.language.isoeng
dc.publisherELECTROCHEMICAL SOC INC
dc.relation.ispartofECS JOURNAL OF SOLID STATE SCIENCE AND TECHNOLOGY
dc.rightsopenAccess
dc.subjectGraphene
dc.subjectPhthalocyanine
dc.subjectHydrogen peroxide (H2O2)
dc.subjectAmperometry
dc.subjectVoltammetry
dc.subjectELECTROCHEMICAL DETERMINATION
dc.subjectELECTROCATALYTIC ACTIVITY
dc.subjectCARBON NANOTUBES
dc.subjectQUANTUM DOTS
dc.subjectSENSOR
dc.subjectNANOPARTICLES
dc.subjectH2O2
dc.subjectGLUCOSE
dc.subjectGOLD
dc.subjectPAPER
dc.subjectMaterials Science
dc.subjectPhysics
dc.titleFabrication of Tetra-Substituted Copper(II) Phthalocyanine-Graphene Modified Pencil Graphite Electrode for Amperometric Detection of Hydrogen Peroxide
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar