Yayın:
Determination of Cadmium in Tap, Sea and Waste Water Samples by Vortex-Assisted Dispersive Liquid-Liquid-Solidified Floating Organic Drop Microextraction and Slotted Quartz Tube FAAS After Complexation with a Imidazole Based Ligand

dc.contributor.authorFindikoglu, Maral Selin
dc.contributor.authorFirat, Merve
dc.contributor.authorChormey, Dotse Selali
dc.contributor.authorTurak, Fatma
dc.contributor.authorSahin, Cigdem
dc.contributor.authorBakirdere, Sezgin
dc.date.accessioned2026-06-27T14:14:32Z
dc.date.issued2018
dc.description.abstractThis study presents a combination of dispersive liquid-liquid-solidified floating organic drop microextraction (DLLSFODM) and slotted quartz tube (SQT) with conventional flame atomic absorption spectrometry (FAAS) to improve the sensitivity for cadmium determination. A ligand namely 2-(4-methylphenyl)-1H-imidazo-[4,5-f]-[1,10]-phenanthroline which has not been used in trace analyte determination was used to form a cadmium complex. Stepwise optimization of parameters affecting complex formation (pH, ligand, and buffer solution) and extraction (extraction and dispersive solvents, salt effect and mixing) was done to maximize cadmium absorbance. The slotted quartz tube was fitted onto the flame burner and optimized to increase residence time of atoms in the flame. Instrumental parameters such as sample and fuel flow rate were also optimized to further enhance the absorbance signal for cadmium. Using optimal parameters and values, the limits of detection and quantification were determined to be 0.81 and 2.69 mu g L-1, respectively. Low percent relative standard deviations (< 6.0%) indicated good precision for both extraction and instrumental measurements. Recovery tests were used to determine the accuracy of the method and the recovery results obtained were between 88 and 113%.en
dc.description.urihttps://doi.org/10.1007/s11270-018-3689-1
dc.identifier.doi10.1007/s11270-018-3689-1
dc.identifier.eissn1573-2932
dc.identifier.issn0049-6979
dc.identifier.issue2
dc.identifier.urihttps://hdl.handle.net/20.500.14981/58351
dc.identifier.volume229
dc.identifier.wos000424317900018
dc.language.isoeng
dc.publisherSPRINGER INTERNATIONAL PUBLISHING AG
dc.relation.ispartofWATER AIR AND SOIL POLLUTION
dc.subjectCadmium
dc.subjectFlame atomic absorption spectrometry
dc.subjectSolidified floating organic drop microextraction
dc.subjectSlotted quartz tube
dc.subjectATOMIC-ABSORPTION-SPECTROMETRY
dc.subjectSENSITIVE DETERMINATION
dc.subjectMASS-SPECTROMETRY
dc.subjectGRAPHITE-FURNACE
dc.subjectTRACE AMOUNT
dc.subjectLEAD
dc.subjectPRECONCENTRATION
dc.subjectCOPPER
dc.subjectTIN
dc.subjectEnvironmental Sciences & Ecology
dc.subjectMeteorology & Atmospheric Sciences
dc.subjectWater Resources
dc.titleDetermination of Cadmium in Tap, Sea and Waste Water Samples by Vortex-Assisted Dispersive Liquid-Liquid-Solidified Floating Organic Drop Microextraction and Slotted Quartz Tube FAAS After Complexation with a Imidazole Based Ligand