Accurate and sensitive determination of selected hormones, endocrine disruptors, and pesticides by gas chromatography-mass spectrometry after the multivariate optimization of switchable solvent liquid-phase microextraction

dc.contributor.authorChormey, Dotse Selali
dc.contributor.authorBodur, Suleyman
dc.contributor.authorBaskin, Dilges
dc.contributor.authorFirat, Merve
dc.contributor.authorBakirdere, Sezgin
dc.date.accessioned2026-06-27T14:13:50Z
dc.date.issued2018
dc.description.abstractSwitchable solvent liquid-phase microextraction was combined with gas chromatography and mass spectrometry to improve the sensitivity and accuracy for the determination of selected endocrine disruptors, pesticides, and hormones. The extraction method was used to complement gas chromatography with mass spectrometry by preconcentrating analytes for trace determinations. A Box-Behnken experimental design was used to evaluate the main variables and their interaction effects, and optimum parameters were selected based on the model of experimented results. Application of optimum extraction conditions to mixed standard solutions yielded limits of detection and quantitation values between 0.20-13 and 0.90-46ng/mL, respectively. The accuracy and the applicability of the developed method was checked in tap water and two different wastewater samples by spiked recovery tests. The percent recoveries recorded for the analytes were between 91 and 110%, and percent relative standard deviation values were all below 10%. The results indicate that the method can be used for the accurate and sensitive determination of these analytes in the presented matrixes.en
dc.description.urihttps://doi.org/10.1002/jssc.201800223
dc.identifier.doi10.1002/jssc.201800223
dc.identifier.eissn1615-9314
dc.identifier.issn1615-9306
dc.identifier.issue14
dc.identifier.pubmed29774656
dc.identifier.urihttps://hdl.handle.net/20.500.14981/58206
dc.identifier.volume41
dc.identifier.wos000439808600004
dc.language.isoeng
dc.publisherWILEY-V C H VERLAG GMBH
dc.relation.ispartofJOURNAL OF SEPARATION SCIENCE
dc.subjectendocrine disruptors
dc.subjecthormones
dc.subjectmultivariate optimization
dc.subjectpesticides
dc.subjectswitchable solvents
dc.subjectALKYLPHENOL ETHOXYLATES
dc.subjectWATER
dc.subjectEXPOSURE
dc.subjectSAMPLES
dc.subjectRISK
dc.subjectChemistry
dc.titleAccurate and sensitive determination of selected hormones, endocrine disruptors, and pesticides by gas chromatography-mass spectrometry after the multivariate optimization of switchable solvent liquid-phase microextraction