Yayın:
Development of a fluorometric measurement system used in biological samples upon the determination of iron (II) metal ion

dc.contributor.authorToksoz, Yavuz Selim
dc.contributor.authorOzyigit, Ibrahim Ethem
dc.contributor.authorBilen, Cigdem
dc.contributor.authorArsu, Nergis
dc.contributor.authorKarakus, Emine
dc.date.accessioned2026-06-27T14:23:54Z
dc.date.issued2021
dc.description.abstract2-thioxanthone thioacetic acid (TXSCH2COOH, T), which has a fluorometric character, was used for new fluorometric system upon Fe(II) analysis in biological samples as the main target. T-BSA binary complex was firstly consisted with non-covalent interactions between T and BSA at the equilibrium concentration as 1.77 x 10(-4.)M. T-BSA binary complex emission was increased at the ratio of 24.40% due to stabilization property of BSA (pH:7), compared with T emission intensity. Fluorescence emission spectroscopy was used for the all measurements because of an economic, a sensitive and a practical method compared with other spectroscopic analysis. T-BSA-Fe(II) triple complex was also obtained by adding Fe(II) ion to T-BSA binary complex solution. Its characterization was performed to be investigated with optimum excitation wavelength, buffer concentration, pH and temperature as 297 nm, 10(-3)M Tris HCl (10(-2)M NaCI), pH:7.2 at 25 degrees C, respectively. The results of Fe(II) analysis in serum showed a certain response in fluorometric T-BSA-Fe(II) triple complex measurement system as 50.42 +/- 5.8 mu g/dL. The analyses of our fluorometric triple complex system were compared with the reference electrochemiluminescence method and similar results were obtained. Fluorometric measurements of T-BSA-Fe(II) triple complex, its characterization and Fe(II) analysis in this system have not been investigated in literature gives originality to our study.en
dc.description.sponsorshipYildiz Technical University Science Research Projects Foundation [FYL-2018-3494]
dc.description.urihttps://doi.org/10.1080/10826068.2020.1818257
dc.identifier.doi10.1080/10826068.2020.1818257
dc.identifier.eissn1532-2297
dc.identifier.endpage374
dc.identifier.issn1082-6068
dc.identifier.issue4
dc.identifier.pubmed32935651
dc.identifier.startpage361
dc.identifier.urihttps://hdl.handle.net/20.500.14981/60162
dc.identifier.volume51
dc.identifier.wos000570006400001
dc.language.isoeng
dc.publisherTAYLOR & FRANCIS INC
dc.relation.ispartofPREPARATIVE BIOCHEMISTRY & BIOTECHNOLOGY
dc.subjectBovine serum albumin
dc.subjectFe(II) analysis
dc.subjectfluorometry
dc.subjectthioxanthone
dc.subjectBOVINE SERUM-ALBUMIN
dc.subjectTIME-RESOLVED FLUOROMETRY
dc.subjectSIDE-CHAIN THIOXANTHONE
dc.subjectNONCOVALENT INTERACTIONS
dc.subjectPHOTOINITIATOR
dc.subjectFLUORESCENCE
dc.subjectBINDING
dc.subjectTECHNOLOGIES
dc.subjectDERIVATIVES
dc.subjectRESOLUTION
dc.subjectBiochemistry & Molecular Biology
dc.subjectBiotechnology & Applied Microbiology
dc.titleDevelopment of a fluorometric measurement system used in biological samples upon the determination of iron (II) metal ion
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar