Yayın: Development of a fluorometric measurement system used in biological samples upon the determination of iron (II) metal ion
| dc.contributor.author | Toksoz, Yavuz Selim | |
| dc.contributor.author | Ozyigit, Ibrahim Ethem | |
| dc.contributor.author | Bilen, Cigdem | |
| dc.contributor.author | Arsu, Nergis | |
| dc.contributor.author | Karakus, Emine | |
| dc.date.accessioned | 2026-06-27T14:23:54Z | |
| dc.date.issued | 2021 | |
| dc.description.abstract | 2-thioxanthone thioacetic acid (TXSCH2COOH, T), which has a fluorometric character, was used for new fluorometric system upon Fe(II) analysis in biological samples as the main target. T-BSA binary complex was firstly consisted with non-covalent interactions between T and BSA at the equilibrium concentration as 1.77 x 10(-4.)M. T-BSA binary complex emission was increased at the ratio of 24.40% due to stabilization property of BSA (pH:7), compared with T emission intensity. Fluorescence emission spectroscopy was used for the all measurements because of an economic, a sensitive and a practical method compared with other spectroscopic analysis. T-BSA-Fe(II) triple complex was also obtained by adding Fe(II) ion to T-BSA binary complex solution. Its characterization was performed to be investigated with optimum excitation wavelength, buffer concentration, pH and temperature as 297 nm, 10(-3)M Tris HCl (10(-2)M NaCI), pH:7.2 at 25 degrees C, respectively. The results of Fe(II) analysis in serum showed a certain response in fluorometric T-BSA-Fe(II) triple complex measurement system as 50.42 +/- 5.8 mu g/dL. The analyses of our fluorometric triple complex system were compared with the reference electrochemiluminescence method and similar results were obtained. Fluorometric measurements of T-BSA-Fe(II) triple complex, its characterization and Fe(II) analysis in this system have not been investigated in literature gives originality to our study. | en |
| dc.description.sponsorship | Yildiz Technical University Science Research Projects Foundation [FYL-2018-3494] | |
| dc.description.uri | https://doi.org/10.1080/10826068.2020.1818257 | |
| dc.identifier.doi | 10.1080/10826068.2020.1818257 | |
| dc.identifier.eissn | 1532-2297 | |
| dc.identifier.endpage | 374 | |
| dc.identifier.issn | 1082-6068 | |
| dc.identifier.issue | 4 | |
| dc.identifier.pubmed | 32935651 | |
| dc.identifier.startpage | 361 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14981/60162 | |
| dc.identifier.volume | 51 | |
| dc.identifier.wos | 000570006400001 | |
| dc.language.iso | eng | |
| dc.publisher | TAYLOR & FRANCIS INC | |
| dc.relation.ispartof | PREPARATIVE BIOCHEMISTRY & BIOTECHNOLOGY | |
| dc.subject | Bovine serum albumin | |
| dc.subject | Fe(II) analysis | |
| dc.subject | fluorometry | |
| dc.subject | thioxanthone | |
| dc.subject | BOVINE SERUM-ALBUMIN | |
| dc.subject | TIME-RESOLVED FLUOROMETRY | |
| dc.subject | SIDE-CHAIN THIOXANTHONE | |
| dc.subject | NONCOVALENT INTERACTIONS | |
| dc.subject | PHOTOINITIATOR | |
| dc.subject | FLUORESCENCE | |
| dc.subject | BINDING | |
| dc.subject | TECHNOLOGIES | |
| dc.subject | DERIVATIVES | |
| dc.subject | RESOLUTION | |
| dc.subject | Biochemistry & Molecular Biology | |
| dc.subject | Biotechnology & Applied Microbiology | |
| dc.title | Development of a fluorometric measurement system used in biological samples upon the determination of iron (II) metal ion | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| local.import.source | WOS |