Yayın:
Determination of Palladium in Precious Metal Waste by Sieve Conducted Two Syringes Pressurized Liquid Phase Microextraction (SCTS-PLPME) and Slotted Quartz Tube Flame Atomic Absorption Spectrometry (SQT-FAAS)

dc.contributor.authorGosterisli, Tugce Unutkan
dc.contributor.authorCesur, Buket
dc.contributor.authorTezgit, Ezgi
dc.contributor.authorBakirdere, Emine Gulhan
dc.contributor.authorKeyf, Seyfullah
dc.contributor.authorBakirdere, Sezgin
dc.date.accessioned2026-06-27T14:37:32Z
dc.date.issued2022
dc.description.abstractDetermination of palladium at trace levels in environmental samples is essential due to its harmful properties and threats to living organisms. Hence, a simple but efficient liquid-phase microextraction method is reported by sieve conducted two syringes pressurized liquid phase microextraction (SCTS-PLPME) and slotted quartz tube flame atomic absorption spectrometry (SQT-FAAS). The originality of this system is based on the elimination of disperser solvents that are used to increase the surface area of extractant. The high pressure created by the movement of syringe plungers results in efficient dispersion of the extractants in the sample solution. Parameters that affect the overall efficiency of the extraction method were carefully optimized. The limit of detection (LOD) and quantification (LOQ) under the optimum conditions were 6.0 and 20.0 mu g L-1, respectively. The developed method showed good linearity between 20 and 1000 mu g L-1, and provided a 25-fold enhancement in detection power compared to conventional FAAS. The optimized method was successfully used to determine the analyte in precious metal waste samples.en
dc.description.sponsorshipScientific and Technological Research Council of Turkey (TUBITAK) [1919B011902716, 2209-A]
dc.description.urihttps://doi.org/10.1080/00032719.2021.1920607
dc.identifier.doi10.1080/00032719.2021.1920607
dc.identifier.eissn1532-236X
dc.identifier.endpage185
dc.identifier.issn0003-2719
dc.identifier.issue2
dc.identifier.startpage175
dc.identifier.urihttps://hdl.handle.net/20.500.14981/62812
dc.identifier.volume55
dc.identifier.wos000701198000001
dc.language.isoeng
dc.publisherTAYLOR & FRANCIS INC
dc.relation.ispartofANALYTICAL LETTERS
dc.subjectFlame atomic absorption spectrometry (FAAS)
dc.subjectliquid-phase microextraction
dc.subjectpalladium
dc.subjectsieve conducted two syringes pressurized liquid phase microextraction (SCTS-PLPME
dc.subjectslotted quartz tube
dc.subjectPLATINUM-GROUP ELEMENTS
dc.subjectTRACE AMOUNTS
dc.subjectPRECONCENTRATION
dc.subjectSAMPLES
dc.subjectWATER
dc.subjectOPTIMIZATION
dc.subjectEXTRACTION
dc.subjectHEALTH
dc.subjectPD(II)
dc.subjectDROP
dc.subjectChemistry
dc.titleDetermination of Palladium in Precious Metal Waste by Sieve Conducted Two Syringes Pressurized Liquid Phase Microextraction (SCTS-PLPME) and Slotted Quartz Tube Flame Atomic Absorption Spectrometry (SQT-FAAS)
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar