Yayın:
An experimental evaluation of electrical skin conductivity changes in postmortem interval and its assessment for time of death estimation

dc.contributor.authorCanturk, Ismail
dc.contributor.authorKarabiber, Fethullah
dc.contributor.authorCelik, Safa
dc.contributor.authorSahin, M. Feyzi
dc.contributor.authorYagmur, Fatih
dc.contributor.authorKara, Sadik
dc.contributor.institutionauthorCANTÜRK, İsmail
dc.date.accessioned2026-06-27T13:49:00Z
dc.date.issued2016
dc.description.abstractIn forensic medicine, estimation of the time of death (ToD) is one of the most important and challenging medico-legal problems. Despite the partial accomplishments in ToD estimations to date, the error margin of ToD estimation is still too large. In this study, electrical conductivity changes were experimentally investigated in the postmortem interval in human cases. Electrical conductivity measurements give some promising clues about the postmortem interval. A living human has a natural electrical conductivity; in the postmortem interval, intracellular fluids gradually leak out of cells. These leaked fluids combine with extra-cellular fluids in tissues and since both fluids are electrolytic, intracellular fluids help increase conductivity. Thus, the level of electrical conductivity is expected to increase with increased time after death. In this study, electrical conductivity tests were applied for six hours. The electrical conductivity of the cases exponentially increased during the tested time period, indicating a positive relationship between electrical conductivity and the postmortem interval. (C) 2015 Elsevier Ltd. All rights reserved.en
dc.description.sponsorshipFatih University [P58011401-B]
dc.description.urihttps://doi.org/10.1016/j.compbiomed.2015.12.010
dc.identifier.doi10.1016/j.compbiomed.2015.12.010
dc.identifier.eissn1879-0534
dc.identifier.endpage96
dc.identifier.issn0010-4825
dc.identifier.pubmed26751404
dc.identifier.startpage92
dc.identifier.urihttps://hdl.handle.net/20.500.14981/55115
dc.identifier.volume69
dc.identifier.wos000371188400010
dc.language.isoeng
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD
dc.relation.ispartofCOMPUTERS IN BIOLOGY AND MEDICINE
dc.subjectTime of death estimation
dc.subjectForensic medicine
dc.subjectPostmortem interval
dc.subjectElectrical conductivity
dc.subjectBody mass index
dc.subjectRIGOR-MORTIS
dc.subjectPHOTOMETRIC MEASUREMENT
dc.subjectBODY-TEMPERATURE
dc.subjectCOOLING RATES
dc.subjectLIVOR-MORTIS
dc.subjectBRAIN
dc.subjectSEQUENCE
dc.subjectMUSCLE
dc.subjectLIVER
dc.subjectPOTASSIUM
dc.subjectLife Sciences & Biomedicine - Other Topics
dc.subjectComputer Science
dc.subjectEngineering
dc.subjectMathematical & Computational Biology
dc.titleAn experimental evaluation of electrical skin conductivity changes in postmortem interval and its assessment for time of death estimation
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar