Yayın:
Eighteen Months Follow-Up with Patient-Centered Outcomes Assessment of Complete Dentures Manufactured Using a Hybrid Nanocomposite and Additive CAD/CAM Protocol

dc.contributor.authorCristache, Corina Marilena
dc.contributor.authorTotu, Eugenia Eftimie
dc.contributor.authorIorgulescu, Gabriela
dc.contributor.authorPantazi, Aida
dc.contributor.authorDorobantu, Dorel
dc.contributor.authorNechifor, Aurelia Cristina
dc.contributor.authorIsildak, Ibrahim
dc.contributor.authorBurlibasa, Mihai
dc.contributor.authorNechifor, Gheorghe
dc.contributor.authorEnachescu, Marius
dc.date.accessioned2026-06-27T14:30:25Z
dc.date.issued2020
dc.description.abstractThe present study aimed to assess the eighteen month follow-up patient-centered outcomes of a simple and predictable protocol for 3D-printed functional complete dentures manufactured using an improved poly(methyl methacrylate) (PMMA)-nanoTiO(2). A detailed morphological and structural characterization of the PMMA-TiO2 nanocomposite, using SEM, EDX, XRD, and AFM, after 3D-printing procedure and post-wearing micro-CT, was also performed. Methods: A total of 35 fully edentulous patients were enrolled in this prospective study. A 0.4% TiO2-nanoparticle-reinforced PMMA composite with improved mechanical strength, morphologically and structurally characterized, was used according to an additive computer-aided design and computer-aided manufacturing (CAD/CAM) protocol for complete denture fabrication. The protocol proposed involved a three-step appointment process. Before denture insertion, 1 week, 12 month, and 18-month follow up patients were evaluated via the Visual Analogue Scale (VAS, 0-10) and Oral Health Impact Profile for Edentulous Patients (OHIP-EDENT), with a higher score meaning poor quality of life. Results: A total of 45 complete denture sets were inserted. OHIP-EDENT scored significantly better after 18 months of denture wearing, 20.43 (+/- 4.42) compared to 52.57 (+/- 8.16) before treatment; mean VAS was improved for all parameters assessed. Conclusions: Within the limitations of this study, we can state that the proposed workflow with the improved material used is a viable treatment option for patients diagnosed with complete edentulism.en
dc.description.sponsorshipRomanian National Authority for Scientific Research and Innovation, CCCDI-UEFISCDI, within PNCDI III [39/2018, 30/2016]
dc.description.sponsorshipINTELMAT contract [PCCDI 39/2018]
dc.description.sponsorshipEuropean Regional Development Fund through Competitiveness Operational Program 2014-2020, Priority axis 1, Innovative Technologies for Materials Quality Assurance in Health, Energy and Environmental - Center for Innovative Manufacturing Solutions of Smart [P_36_611, 107066]
dc.description.urihttps://doi.org/10.3390/jcm9020324
dc.identifier.doi10.3390/jcm9020324
dc.identifier.eissn2077-0383
dc.identifier.issue2
dc.identifier.pubmed31979345
dc.identifier.urihttps://hdl.handle.net/20.500.14981/61414
dc.identifier.volume9
dc.identifier.wos000518823000037
dc.language.isoeng
dc.publisherMDPI
dc.relation.ispartofJOURNAL OF CLINICAL MEDICINE
dc.rightsopenAccess
dc.subjectPMMA-nanotitania composite
dc.subjectOHIP-EDENT
dc.subjectdigital light processing
dc.subjectcomplete denture
dc.subjectquality of life
dc.subjectPOLY(METHYL METHACRYLATE)
dc.subjectCHEMICAL CHARACTERISTICS
dc.subjectNANOINDENTATION
dc.subjectADAPTATION
dc.subjectGeneral & Internal Medicine
dc.titleEighteen Months Follow-Up with Patient-Centered Outcomes Assessment of Complete Dentures Manufactured Using a Hybrid Nanocomposite and Additive CAD/CAM Protocol
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar