Yayın: Eighteen Months Follow-Up with Patient-Centered Outcomes Assessment of Complete Dentures Manufactured Using a Hybrid Nanocomposite and Additive CAD/CAM Protocol
| dc.contributor.author | Cristache, Corina Marilena | |
| dc.contributor.author | Totu, Eugenia Eftimie | |
| dc.contributor.author | Iorgulescu, Gabriela | |
| dc.contributor.author | Pantazi, Aida | |
| dc.contributor.author | Dorobantu, Dorel | |
| dc.contributor.author | Nechifor, Aurelia Cristina | |
| dc.contributor.author | Isildak, Ibrahim | |
| dc.contributor.author | Burlibasa, Mihai | |
| dc.contributor.author | Nechifor, Gheorghe | |
| dc.contributor.author | Enachescu, Marius | |
| dc.date.accessioned | 2026-06-27T14:30:25Z | |
| dc.date.issued | 2020 | |
| dc.description.abstract | The present study aimed to assess the eighteen month follow-up patient-centered outcomes of a simple and predictable protocol for 3D-printed functional complete dentures manufactured using an improved poly(methyl methacrylate) (PMMA)-nanoTiO(2). A detailed morphological and structural characterization of the PMMA-TiO2 nanocomposite, using SEM, EDX, XRD, and AFM, after 3D-printing procedure and post-wearing micro-CT, was also performed. Methods: A total of 35 fully edentulous patients were enrolled in this prospective study. A 0.4% TiO2-nanoparticle-reinforced PMMA composite with improved mechanical strength, morphologically and structurally characterized, was used according to an additive computer-aided design and computer-aided manufacturing (CAD/CAM) protocol for complete denture fabrication. The protocol proposed involved a three-step appointment process. Before denture insertion, 1 week, 12 month, and 18-month follow up patients were evaluated via the Visual Analogue Scale (VAS, 0-10) and Oral Health Impact Profile for Edentulous Patients (OHIP-EDENT), with a higher score meaning poor quality of life. Results: A total of 45 complete denture sets were inserted. OHIP-EDENT scored significantly better after 18 months of denture wearing, 20.43 (+/- 4.42) compared to 52.57 (+/- 8.16) before treatment; mean VAS was improved for all parameters assessed. Conclusions: Within the limitations of this study, we can state that the proposed workflow with the improved material used is a viable treatment option for patients diagnosed with complete edentulism. | en |
| dc.description.sponsorship | Romanian National Authority for Scientific Research and Innovation, CCCDI-UEFISCDI, within PNCDI III [39/2018, 30/2016] | |
| dc.description.sponsorship | INTELMAT contract [PCCDI 39/2018] | |
| dc.description.sponsorship | European Regional Development Fund through Competitiveness Operational Program 2014-2020, Priority axis 1, Innovative Technologies for Materials Quality Assurance in Health, Energy and Environmental - Center for Innovative Manufacturing Solutions of Smart [P_36_611, 107066] | |
| dc.description.uri | https://doi.org/10.3390/jcm9020324 | |
| dc.identifier.doi | 10.3390/jcm9020324 | |
| dc.identifier.eissn | 2077-0383 | |
| dc.identifier.issue | 2 | |
| dc.identifier.pubmed | 31979345 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14981/61414 | |
| dc.identifier.volume | 9 | |
| dc.identifier.wos | 000518823000037 | |
| dc.language.iso | eng | |
| dc.publisher | MDPI | |
| dc.relation.ispartof | JOURNAL OF CLINICAL MEDICINE | |
| dc.rights | openAccess | |
| dc.subject | PMMA-nanotitania composite | |
| dc.subject | OHIP-EDENT | |
| dc.subject | digital light processing | |
| dc.subject | complete denture | |
| dc.subject | quality of life | |
| dc.subject | POLY(METHYL METHACRYLATE) | |
| dc.subject | CHEMICAL CHARACTERISTICS | |
| dc.subject | NANOINDENTATION | |
| dc.subject | ADAPTATION | |
| dc.subject | General & Internal Medicine | |
| dc.title | Eighteen Months Follow-Up with Patient-Centered Outcomes Assessment of Complete Dentures Manufactured Using a Hybrid Nanocomposite and Additive CAD/CAM Protocol | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| local.import.source | WOS |