Yayın:
Potentiometric urea biosensors

dc.contributor.authorOzbek, Oguz
dc.contributor.authorBerkel, Caglar
dc.contributor.authorIsildak, Omer
dc.contributor.authorIsildak, Ibrahim
dc.date.accessioned2026-06-27T14:46:03Z
dc.date.issued2022
dc.description.abstractExcess nitrogen in the body is converted to urea in the liver, and urea is disposed as a waste product in urine. Urea concentration can change in body fluids such as blood due to the presence of certain disorders. Therefore, the determination of urea is of high importance in various areas including medical diagnosis, as well as food quality control and environmental monitoring. Potentiometric sensors have certain advantages over their alternatives, such as rapidity, portability, cost effectiveness, high sensitivity, easy operation and simple apparatus. Potentiometric urea biosensors based on enzyme urease have been developed using various materials including nanoparticles and films, and also using different methodologies. In this review, we covered potentiometric urea biosensors reported in the literature, and touched upon their certain structure characteristics and performance parameters including detection limit, working concentration range, response time and lifetime, all of which are of practical importance. Each potentiometric urea biosensor has its own advantages and drawbacks, thus the selection of appropriate method depends on the sample to be analyzed, its urea concentration range and other requirements of the particular application. Further research is needed in order to optimize the performance of these devices and to broaden their applicability.en
dc.description.sponsorshipScientific and Technological Research Council of Turkey (TUBITAK) 2211-A program
dc.description.sponsorshipScientific and Technological Research Council of Turkey (TUBITAK) 2211-E program
dc.description.sponsorshipTUBITAK
dc.description.urihttps://doi.org/10.1016/j.cca.2021.11.011
dc.identifier.doi10.1016/j.cca.2021.11.011
dc.identifier.eissn1873-3492
dc.identifier.endpage163
dc.identifier.issn0009-8981
dc.identifier.pubmed34774544
dc.identifier.startpage154
dc.identifier.urihttps://hdl.handle.net/20.500.14981/64510
dc.identifier.volume524
dc.identifier.wos000790634000020
dc.language.isoeng
dc.publisherELSEVIER
dc.relation.ispartofCLINICA CHIMICA ACTA
dc.rightsopenAccess
dc.subjectUrea
dc.subjectPotentiometry
dc.subjectBiosensor
dc.subjectBiomedical analysis
dc.subjectClinical chemistry
dc.subjectMedical diagnosis
dc.subjectRECOMBINANT UREASE
dc.subjectCARBON NANOTUBES
dc.subjectSENSOR
dc.subjectELECTRODE
dc.subjectIMMOBILIZATION
dc.subjectNANOPARTICLES
dc.subjectPOLYANILINE
dc.subjectMEMBRANE
dc.subjectCOMPLEX
dc.subjectSYSTEM
dc.subjectMedical Laboratory Technology
dc.titlePotentiometric urea biosensors
dc.typeReview
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar