Yayın:
An accurate analytical method for the determination of antimony in tea and tap water samples: photochemical vapor generation-atom trapping prior to FAAS measurement

dc.contributor.authorYazici, Elif
dc.contributor.authorBuyukpinar, Cagdas
dc.contributor.authorBodur, Suleyman
dc.contributor.authorSan, Nevim
dc.contributor.authorKomesli, Okan Tarik
dc.contributor.authorBakirdere, Sezgin
dc.date.accessioned2026-06-27T14:33:53Z
dc.date.issued2021
dc.description.abstractA sensitive and accurate sonication-assisted gas liquid separator-photochemical vapor generation-T-shaped slotted quartz tube with seven exit holes-atom trapping-flame atomic absorption spectrophotometry (SA-GLS-PVG-T-SQT-AT-FAAS) system was developed for the quantification of antimony at trace levels in daphne tea and tap water samples. A comprehensive univariate optimization was utilized to evaluate experimental conditions in terms of flame type, hydrogen gas flow rate, argon gas flow rate, trapping period, type of T-SQT and height of T-SQT. Under the conditions optimized, limit of detection (LOD) and limit of quantification values for the proposed method were figured out as 28.4 and 94.5 mu g/L, respectively. Increment in detection power was recorded as 96-folds when LOD values of the FAAS, and the SA-GLS-PVG-T-SQT-AT-FAAS systems were compared to each other. Spiking experiments were also carried out for the evaluation of the method's applicability and accuracy. Percent recovery results for both samples were found in the range of 90.2-108.0% using the SA-GLS-PVG-T-SQT-AT-FAAS system.en
dc.description.sponsorshipScientific and Technological Research Council of Turkey (TuBTAK) [117Z380]
dc.description.urihttps://doi.org/10.1007/s11696-021-01569-z
dc.identifier.doi10.1007/s11696-021-01569-z
dc.identifier.eissn2585-7290
dc.identifier.endpage3316
dc.identifier.issn0366-6352
dc.identifier.issue7
dc.identifier.startpage3309
dc.identifier.urihttps://hdl.handle.net/20.500.14981/62125
dc.identifier.volume75
dc.identifier.wos000624368600001
dc.language.isoeng
dc.publisherSPRINGER INT PUBL AG
dc.relation.ispartofCHEMICAL PAPERS
dc.subjectT-shaped slotted quartz tube-atom trapping
dc.subjectAntimony
dc.subjectFlame atomic absorption spectrophotometry
dc.subjectPhotochemical vapor generation
dc.subjectChemistry
dc.titleAn accurate analytical method for the determination of antimony in tea and tap water samples: photochemical vapor generation-atom trapping prior to FAAS measurement
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar