Insulation evaluation of MV underground cable with partial discharge and dielectric dissipation factor measurements

dc.contributor.authorArikan, Oktay
dc.contributor.authorUydur, Cihat Cagdas
dc.contributor.authorKumru, Celal Fadil
dc.date.accessioned2026-06-27T14:49:37Z
dc.date.issued2023
dc.description.abstractAs it is known overvoltage and impulse voltage are the most common stresses that cables are exposed to in practice. Since the occurrence frequency, duration and amplitude of these two stresses are different, their deteriorating effects on the cable insulation also differ. At this point, it is necessary to know how sensitively the preferred dielectric diagnosis method can detect the deteriorations on cable insulation. Since it is not technically possible to detect all isolation errors with a single preferred diagnostic method, the methods must be used together in a certain procedure. In this study, 12/20.8 kV, XLPE insulated Cable Samples were artificially aged using 50 aging cycles of overvoltage (36 kV and 60 kV) and 50 kV, standard positive impulse voltage. After each aging cycle, dielectric performance of cable insulation was measured using partial discharge (PD) and dielectric dissipation factor (DDF) methods. The accuracy of dielectric diagnosis methods due to overvoltage and impulse voltage are analyzed and discussed based on the measurement results. In order to analyze dielectric diagnostic performances of the methods, both individual trends and the correlation between PD and DDF parameters during overvoltage and impulse voltage aging processes were shared. As a result, it was found that diagnostic perfor-mances of PD and DDF methods differ according to the amplitude and waveform of the applied electrical stress. Therefore, a dielectric diagnosis procedure for MV cables including both PD and DDF methods to improve diagnostic process in field applications was proposed. In this context, the use of the proposed diagnosis procedure will contribute to the evaluation of the findings resulting from the diagnostic methods during the operation of MV cables.en
dc.description.sponsorshipScientific Research Project Coordinator of Yildiz Technical Univer- sity [FDK- 2020-3897]
dc.description.sponsorshipYildiz Technical University
dc.description.urihttps://doi.org/10.1016/j.epsr.2023.109338
dc.identifier.doi10.1016/j.epsr.2023.109338
dc.identifier.eissn1873-2046
dc.identifier.issn0378-7796
dc.identifier.urihttps://hdl.handle.net/20.500.14981/65255
dc.identifier.volume220
dc.identifier.wos000957675900001
dc.language.isoeng
dc.publisherELSEVIER SCIENCE SA
dc.relation.ispartofELECTRIC POWER SYSTEMS RESEARCH
dc.subjectDiagnosis procedure
dc.subjectDissipation factor
dc.subjectElectrical stresses
dc.subjectPartial discharge
dc.subjectOperation of XLPE cable
dc.subjectLOW-FREQUENCY
dc.subjectKV XLPE
dc.subjectVOLTAGE
dc.subjectVLF
dc.subjectEngineering
dc.titleInsulation evaluation of MV underground cable with partial discharge and dielectric dissipation factor measurements
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar