THEORETICAL ANALYSIS ON THE PREDICTION OF PERFORMANCE COEFFICIENT OF TWO-STAGE CASCADE REFRIGERATION SYSTEM USING VARIOUS ALTERNATIVE REFRIGERANTS

Yükleniyor...
Küçük Resim

Tarih

Kurum Yazarları

Item type:Araştırmacı/Yazar,
DALKILIÇ, Ahmet Selim

Danışman

item.page.editor

Editör

Bölüm / Program

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

TURKISH SOC THERMAL SCIENCES TECHNOLOGY

DOI

Türü

Araştırma Projeleri

Akademik Birimler

Dergi Sayısı

Özet

This paper presents a comparison of the refrigerants CFC-12, HCFC-22, CFC-502, and their alternatives, such as HFC-134a, HFC-152a, HFC-404A, HFC-407C, HC-290, HC-600a, R717 (ammonia), and three mixtures composed of HFC-134a, HFC-152a, HC-600a, and HC-290. A theoretical performance study on a cascade refrigeration system was performed using two refrigeration cycles connected through a heat exchanger in the middle working as an evaporator for the high-pressure cycle and a condenser for the low-pressure cycle. The condensing temperatures varied between 40 and 60 degrees C, the evaporating temperatures varied between -50 and -10 degrees C, and the heat exchanger temperature was kept constant at 1 degrees C. The refrigerants in both cycles are assumed to be same at first. The alternative refrigerants of HFC-152a and R717 had higher coefficients of performance (COPs) than other refrigerants and also low refrigerant charge rates for all operating conditions in the case study, according to the results of the theoretical analysis. The effects of the investigated refrigerants on the depletion of the ozone layer, increase in global warming, and flammable and toxic characteristics were considered and alternative refrigerant mixtures that may be suggested were determined. It was found that refrigerant blends of HC290/HC600a (55/45 by wt%), as a non-azeotropic mixture, and HFC-152a/HFC-134a (14/86 by wt%) and HFC-134a/HC600a (82/18 by wt%), as azeotropic mixtures, gave lower performance coefficients (COPs) and required lower refrigerant charge rates than their base pure refrigerants in the analysis. The separate usage of the refrigerants R717 and HFC-152a for the high- and low-pressure sections of the cascade system, respectively, were found to be the best combination in terms of the analysis for the determination of coefficients of performance (COP) and refrigerant charge rates. The results of this study are of technological importance for efficient design when the industrial systems are assigned to utilize various alternative refrigerants.

Tanım

Dergi veya Seri

ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY

ISSN

1300-3615

ISBN

Haklar

Alıntı

Koleksiyonlar

Onay

Gözden geçir

Tamamlayıcı Bilgiler

Referans Gösteren

Related Patent

Related Goal

0

Views

0

Downloads