Yayın:
In-silico Evaluation of the effects of blood flow rate change in ductus arteriosus on cardiac function and cerebral blood flow rate in term and preterm infants

dc.contributor.authorBozkurt, Surhan
dc.contributor.authorBal, Ridvan
dc.contributor.authorAyten, Umut Engin
dc.date.accessioned2026-06-27T15:00:34Z
dc.date.issued2024
dc.description.abstractThe transition of cardiovascular system is vital for newborn infants. It is expected that ductus arteriosus which is vessel between aorta and pulmonary arteries closes in the first day of life. However, ductus arteriosus may not close within 24 h in preterm infants. In this study, a lumped parameter model was used to evaluate the effects of the change in blood flow rate through ductus arteriosus on cardiac function and cerebral blood flow rate in term and preterm neonatal infants. Mean arterial pressure increased from 41 mmHg to 53 mmHg at 24th hour after birth in term neonatal infant cardiovascular system model whereas it increased from 33 mmHg to 43 mmHg in preterm neonatal infant cardiovascular system model. Left cardiac output decreased from 911 mL/min to 721 mL/min and right cardiac output increased 551 mL/min to 706 mL/min in term neonatal infant cardiovascular system model. Left cardiac output decreased from 705 mL/min to 612 mL/min and right cardiac output increased 369 mL/min to 484 mL/min in preterm neonatal infant cardiovascular system model. Cerebral blood flow rate increased from 115 mL/min to 147.40 mL/min in term neonatal infant cardiovascular system model at 24th hour after birth and it increased 29.65 mL/min to 38.92 mL/min in preterm neonatal cardiovascular system model. The results showed that blood flow rate through ductus arteriosus alters cardiac function and cerebral blood flow rate in both term and preterm cardiovascular system models.en
dc.description.urihttps://doi.org/10.1016/j.bspc.2024.106696
dc.identifier.doi10.1016/j.bspc.2024.106696
dc.identifier.eissn1746-8108
dc.identifier.issn1746-8094
dc.identifier.urihttps://hdl.handle.net/20.500.14981/67087
dc.identifier.volume97
dc.identifier.wos001291037500001
dc.language.isoeng
dc.publisherELSEVIER SCI LTD
dc.relation.ispartofBIOMEDICAL SIGNAL PROCESSING AND CONTROL
dc.subjectNeonatal infant cardiovascular system model
dc.subjectCardiac function
dc.subjectCerebral blood flow rate
dc.subjectECHOCARDIOGRAPHIC MEASUREMENTS
dc.subjectTRANSITION
dc.subjectHEMODYNAMICS
dc.subjectCIRCULATION
dc.subjectPRESSURE
dc.subjectVELOCITY
dc.subjectMODEL
dc.subjectEngineering
dc.titleIn-silico Evaluation of the effects of blood flow rate change in ductus arteriosus on cardiac function and cerebral blood flow rate in term and preterm infants
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar