Yayın:
Trace Level Determination of Cadmium in Different Water Matrices and Rose Hip Tea Sample by Dispersive Liquid-liquid Microextraction Slotted Quartz Tube Flame Atomic Absorption Spectrometry After Complexation With a New Imidazole-based Ligand

dc.contributor.authorYazici, Elif
dc.contributor.authorFirat, Merve
dc.contributor.authorChormey, Dotse Selali
dc.contributor.authorBudak, Turkan Borklu
dc.contributor.authorSahin, Cigdem
dc.contributor.authorTurak, Fatma
dc.contributor.authorBakirdere, Sezgin
dc.date.accessioned2026-06-27T14:21:51Z
dc.date.issued2019
dc.description.abstractThis study presents a sensitive, accurate, and precise analytical method for the determination of cadmium in water samples. A laboratory synthesized imidazole-based ligand (2-(4-methylphenyl)1H-imidazo-[4,5-f]-[1,10]-phenanthroline) was used to form a cadmium complex for extraction by dispersive liquid-liquid microextraction (DLLM). Optimization of complexation, extraction, and instrumental parameters led to a 74-fold enhancement in the detection power of FAAS. The limits of detection and quantification were found at 0.57 and 1.9 mu g/L, respectively. The relative standard deviation of the method was less than 5.0%, indicating high precision for the experimental process. Accuracy and applicability of the method were tested on environmental (tap, well, and wastewater) and drink (rose hip tea) samples at different spiking concentrations, and satisfactory recovery results were obtained between 88 and 112%.en
dc.description.urihttps://doi.org/10.46770/as.2019.01.004
dc.identifier.doi10.46770/as.2019.01.004
dc.identifier.eissn2708-521X
dc.identifier.endpage30
dc.identifier.issn0195-5373
dc.identifier.issue1
dc.identifier.startpage24
dc.identifier.urihttps://hdl.handle.net/20.500.14981/59733
dc.identifier.volume40
dc.identifier.wos000466279600004
dc.language.isoeng
dc.publisherATOMIC SPECTROSCOPY PRESS LTD
dc.relation.ispartofATOMIC SPECTROSCOPY
dc.rightsopenAccess
dc.subjectVAPOR GENERATION
dc.subjectEXTRACTION
dc.subjectLEAD
dc.subjectPERFORMANCE
dc.subjectSpectroscopy
dc.titleTrace Level Determination of Cadmium in Different Water Matrices and Rose Hip Tea Sample by Dispersive Liquid-liquid Microextraction Slotted Quartz Tube Flame Atomic Absorption Spectrometry After Complexation With a New Imidazole-based Ligand
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar