Yayın:
Induction motors bearing failures detection and diagnosis:: Park and concordia transform approaches comparative study

dc.contributor.authorOenel, I. Y.
dc.contributor.authorBenbouzid, M. E. H.
dc.date.accessioned2026-06-27T13:04:48Z
dc.date.issued2007
dc.description.abstractThis paper deals with the problem of bearing failure detection and diagnosis in induction motors. Indeed, bearings deterioration is now the main cause of induction motor rotor failures. In this context, two fault detection and diagnosis techniques, namely the Park transform approach and the Concordia transform, are briefly presented and compared. Experimental tests, on a 0.75-kW two-pole induction motor with artificial bearing damages, outline the above approaches main features for small and medium size induction motors bearing failure detection and/or diagnosis.en
dc.description.urihttps://doi.org/10.1109/iemdc.2007.382825
dc.identifier.doi10.1109/iemdc.2007.382825
dc.identifier.endpage+
dc.identifier.isbn978-1-4244-0742-2
dc.identifier.startpage1073
dc.identifier.urihttps://hdl.handle.net/20.500.14981/49418
dc.identifier.wos000248118800189
dc.language.isoeng
dc.publisherIEEE
dc.relation.conferenceIEEE International Electric Machines and Drives Conference (IEMDC 2007)
dc.relation.ispartofIEEE IEMDC 2007: PROCEEDINGS OF THE INTERNATIONAL ELECTRIC MACHINES AND DRIVES CONFERENCE, VOLS 1 AND 2
dc.subjectinduction motor
dc.subjectbearing failure
dc.subjectfault
dc.subjectdetection
dc.subjectdiagnosis
dc.subjectPark transform
dc.subjectConcordia transform
dc.subjectAutomation & Control Systems
dc.subjectEngineering
dc.subjectTransportation