Yayın: Realistic experimental heat transfer characteristics of radiant floor heating using sidewalls as heat sinks
| dc.contributor.author | Acikgoz, Ozgen | |
| dc.contributor.author | Karakoyun, Yakup | |
| dc.contributor.author | Yumurtaci, Zehra | |
| dc.contributor.author | Dukhan, Nihad | |
| dc.contributor.author | Dalkilic, Ahmet Selim | |
| dc.date.accessioned | 2026-06-27T14:22:08Z | |
| dc.date.issued | 2019 | |
| dc.description.abstract | Apart from most of the relevant literature, case studies are conducted by generating a number of configurations using sidewalls as heat sinks to simulate winter conditions. These configurations correspond to distinct heat loss rates and means from a living environment, heated by an underfloor heating system. In this study, heat transfer characteristics of an underfloor heating system in a test chamber have been experimentally determined, while chilled water flows through circuits in sidewalls arranged at four different configurations. Simultaneously, supply water temperatures ranging from 30 degrees C to 45 degrees C, and a flow rate of 0.09 kg/s are applied. As a result, when the supply water temperature is 35 degrees C, with increasing number of cooled sidewalls, at configuration 2, 3, and 4 as increasing heat loss sources, total heat fluxes from the floor are found 66.36 W/m(2), 81.79 W/m(2), and 85.19 W/m(2), respectively. Correlations for the convective heat transfer coefficient and total heat flux are derived and average error rates of +/- 11% and +/- 4.5% are obtained, as 87.5% and 94% of measured data remain in +/- 30% and +/- 10% error bands considering the derived empirical correlations, respectively. Measured and calculated data are given for other researchers to validate their models. (C) 2018 Elsevier B.V. All rights reserved. | en |
| dc.description.sponsorship | Yildiz Technical University Scientific Research Projects Coordination Department [2015-06-01-KAP02] | |
| dc.description.uri | https://doi.org/10.1016/j.enbuild.2018.11.022 | |
| dc.identifier.doi | 10.1016/j.enbuild.2018.11.022 | |
| dc.identifier.eissn | 1872-6178 | |
| dc.identifier.endpage | 526 | |
| dc.identifier.issn | 0378-7788 | |
| dc.identifier.startpage | 515 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14981/59791 | |
| dc.identifier.volume | 183 | |
| dc.identifier.wos | 000456760000038 | |
| dc.language.iso | eng | |
| dc.publisher | ELSEVIER SCIENCE SA | |
| dc.relation.ispartof | ENERGY AND BUILDINGS | |
| dc.subject | Natural convection | |
| dc.subject | Enclosure | |
| dc.subject | Radiant heating | |
| dc.subject | Floor heating | |
| dc.subject | Energy saving | |
| dc.subject | TRANSFER COEFFICIENTS | |
| dc.subject | THERMAL PERFORMANCE | |
| dc.subject | SYSTEMS | |
| dc.subject | PUMP | |
| dc.subject | WALL | |
| dc.subject | CONVECTION | |
| dc.subject | Construction & Building Technology | |
| dc.subject | Energy & Fuels | |
| dc.subject | Engineering | |
| dc.title | Realistic experimental heat transfer characteristics of radiant floor heating using sidewalls as heat sinks | |