Yayın: T-cut slotted quartz tube-atom trap strategy for the on-line preconcentration of thallium in well water samples
| dc.contributor.author | Bombom, Miray | |
| dc.contributor.author | Zaman, Buse Tugba | |
| dc.contributor.author | Bozyigit, Gamze Dalgic | |
| dc.contributor.author | Saylan, Meltem | |
| dc.contributor.author | Bayraktar, Ahsen | |
| dc.contributor.author | Arvas, Busra | |
| dc.contributor.author | Yolacan, Cigdem | |
| dc.contributor.author | Bakirdere, Sezgin | |
| dc.date.accessioned | 2026-06-27T14:55:22Z | |
| dc.date.issued | 2023 | |
| dc.description.abstract | In this study, an on-line preconcentration system was developed for the quantitative determination of thallium in well water samples using hydrogen-assisted T-cut slotted quartz tube atom trapping (HA-T-SQT-AT) coupled to flame atomic absorption spectrometry (FAAS). The method is based on trapping the thallium atoms on the inner surface of the T-SQT for a short period using sample aspiration and lean flame conditions. Then, hydrogen gas as a reducing agent was released instantly to free the trapped analyte atoms, resulting in a sharp and narrow signal. The system analytical performance was enhanced by performing comprehensive optimization of several factors. The linear range and LOD/LOQ values of the optimized method were found to be 7.5---200 ng/mL and 2.6/8.7 ng/mL, respectively. Accuracy/practicability of the presented method were verified using well water samples, and the percent recoveries calculated using the external calibration approach were all above 80%. | en |
| dc.description.sponsorship | Scientific and Technological Research Council of Turkey (TUEBITAK) [1919B012100881] | |
| dc.description.uri | https://doi.org/10.1016/j.measurement.2023.113363 | |
| dc.identifier.doi | 10.1016/j.measurement.2023.113363 | |
| dc.identifier.eissn | 1873-412X | |
| dc.identifier.issn | 0263-2241 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14981/66254 | |
| dc.identifier.volume | 220 | |
| dc.identifier.wos | 001048966200001 | |
| dc.language.iso | eng | |
| dc.publisher | ELSEVIER SCI LTD | |
| dc.relation.ispartof | MEASUREMENT | |
| dc.subject | Thallium | |
| dc.subject | Flame atomic absorption spectrometry | |
| dc.subject | Atom trap | |
| dc.subject | T-shaped slotted quartz tube | |
| dc.subject | Well water | |
| dc.subject | CLOUD POINT EXTRACTION | |
| dc.subject | ABSORPTION-SPECTROMETRY | |
| dc.subject | ICP-OES | |
| dc.subject | GENERATION | |
| dc.subject | INDIUM | |
| dc.subject | Engineering | |
| dc.subject | Instruments & Instrumentation | |
| dc.title | T-cut slotted quartz tube-atom trap strategy for the on-line preconcentration of thallium in well water samples | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| local.import.source | WOS |