Yayın:
Treatment of textile wastewater in combined granular activated carbon- membrane bioreactor (GAC-MBR)

dc.contributor.authorTecirli, Emine Sule
dc.contributor.authorAkgun, Kadir
dc.contributor.authorCaglak, Abdulkadir
dc.contributor.authorErkan, Hanife
dc.contributor.authorOnkal Engin, Guleda
dc.date.accessioned2026-06-27T14:59:16Z
dc.date.issued2024
dc.description.abstractIn recent years, the membrane bioreactor (MBR) process has been seen as a promising technology for the treatment of both municipal and industrial wastewater, including textile wastewater which has the potential to generate high levels of pollution in the receiving environment. However, membrane fouling during MBR operation is seen as one of the most important drawbacks due to the reduction of membrane flux. In this study, granular activated carbon MBR (GAC-MBR) technology was investigated to treat real textile wastewater. In this context, conventional MBR (R1) and GAC-MBR (R2) with GAC (300 mg) were operated for 48 days. A flat-plate ceramic membrane module was used in both reactors. The chemical oxygen demand (COD) and color removal efficiencies were found to be 87 +/- 3% and 73 +/- 7% in conventional MBR, whereas these pollutant removal efficiencies were determined as 89 +/- 6.4% and 78 +/- 4.8%, respectively, in the GAC-MBR process. According to the results obtained, while conventional MBR required physical cleaning every other day, GAC-MBR did not require any cleaning after the addition of GAC. It was also observed that GAC had no direct effects on the excretion of soluble and loosely-bound or tightly-bound extracellular polymeric substances, however, reduced the transmembrane pressure, capillary suction time, and membrane fouling propensity.en
dc.description.sponsorshipScientific and Technological Research Council of Turkey (TUBITAK) [2209-A]
dc.description.urihttps://doi.org/10.14744/sigma.2024.00115115
dc.identifier.doi10.14744/sigma.2024.00115115
dc.identifier.eissn1304-7191
dc.identifier.endpage1499
dc.identifier.issn1304-7205
dc.identifier.issue5
dc.identifier.startpage1490
dc.identifier.urihttps://hdl.handle.net/20.500.14981/66804
dc.identifier.volume42
dc.identifier.wos001339231600014
dc.language.isoeng
dc.publisherYILDIZ TECHNICAL UNIV
dc.relation.ispartofSIGMA JOURNAL OF ENGINEERING AND NATURAL SCIENCES-SIGMA MUHENDISLIK VE FEN BILIMLERI DERGISI
dc.subjectGranular Activated Carbon
dc.subjectMembrane Bioreactor
dc.subjectMembrane Fouling
dc.subjectTextile Wastewater
dc.subjectENHANCED PERFORMANCE
dc.subjectFOULING REDUCTION
dc.subjectSLUDGE
dc.subjectDEWATERABILITY
dc.subjectSAMBR
dc.subjectPAC
dc.subjectEngineering
dc.titleTreatment of textile wastewater in combined granular activated carbon- membrane bioreactor (GAC-MBR)
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar