Yayın:
Sensitive determination of bismuth by flame atomic absorption spectrometry using atom trapping in a slotted quartz tube and revolatilization with organic solvent pulse

dc.contributor.authorKilinc, Ersin
dc.contributor.authorBakirdere, Sezgin
dc.contributor.authorAydin, Firat
dc.contributor.authorAtaman, O. Yavuz
dc.contributor.institutionauthorBAKIRDERE, Sezgin
dc.date.accessioned2026-06-27T13:18:25Z
dc.date.issued2012
dc.description.abstractSensitivity of flame atomic absorption spectrometry (FAAS) for Bi determination was improved by slotted quartz tube (SQT) that was used also for atom trapping (AT). The trapped analyte was released by aspirating a small volume of organic solvent after a reasonable analyte collection time. Sensitivity was improved by 2.9 times by SQT-FAAS and 256 times by SQT-AT-FAAS with respect to FAAS. Optimum trapping period was found to be 6.0 min (36.0 mL of solution). Limit of detection (LOD) for SQT-AT-FAAS was found to be 1.6 ng mL(-1). %RSD was calculated as 4.0% for five replicate measurements of 7.5 ng mL(-1) Bi by SQT-AT-FAAS. Accuracy of the method developed was checked by analyzing a standard reference material of simulated fresh water (NIST 1643e) and result found was in good agreement with the certified one. The method can be applied in any laboratory equipped with a flame AA spectrometer. The consumption of time and sample volume is fairly low and application is simple and easy. (C) 2012 Elsevier B.V. All rights reserved.en
dc.description.sponsorshipUniversity of Dicle (DUBAP) [10-FF-31]
dc.description.sponsorshipTUBITAK-BIDEP
dc.description.sponsorshipTUBITAK [109T239]
dc.description.urihttps://doi.org/10.1016/j.sab.2012.06.004
dc.identifier.doi10.1016/j.sab.2012.06.004
dc.identifier.endpage88
dc.identifier.issn0584-8547
dc.identifier.startpage84
dc.identifier.urihttps://hdl.handle.net/20.500.14981/51718
dc.identifier.volume73
dc.identifier.wos000308281000014
dc.language.isoeng
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD
dc.relation.ispartofSPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY
dc.rightsopenAccess
dc.subjectBismuth
dc.subjectSlotted quartz tube
dc.subjectAtom trapping
dc.subjectFlame AAS
dc.subjectCLOUD POINT EXTRACTION
dc.subjectENVIRONMENTAL-SAMPLES
dc.subjectSPECTROPHOTOMETRIC DETERMINATION
dc.subjectTRACE-ELEMENTS
dc.subjectWATER SAMPLES
dc.subjectGENERATION
dc.subjectAAS
dc.subjectPRECONCENTRATION
dc.subjectINTERFERENCE
dc.subjectSYSTEM
dc.subjectSpectroscopy
dc.titleSensitive determination of bismuth by flame atomic absorption spectrometry using atom trapping in a slotted quartz tube and revolatilization with organic solvent pulse
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar