Yayın:
Study of time resolution measurements and prospects for energy resolution of an ultra-compact sampling calorimeter (RADiCAL) module at EM shower maximum over the energy range 25 GeV 150 GeV

Yükleniyor...
Küçük Resim

Tarih

Kurum Yazarları

Danışman

item.page.editor

Editör

Bölüm / Program

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

ELSEVIER

DOI

10.1016/j.nima.2024.169737

Türü

View PlumX Details

Araştırma Projeleri

Akademik Birimler

Dergi Sayısı

Özet

The RADiCAL Collaboration is conducting R&D on high performance electromagnetic (EM) calorimetry to address the challenges expected in future collider experiments under conditions of high luminosity and/or high irradiation (FCC-ee, FCC-hh, fixed target and forward physics environments). Under development is a sampling calorimeter approach, known as RADiCAL modules, based on scintillation, wavelength-shifting (WLS) technologies and photosensor, including SiPM or SiPM-like technology. The modules discussed herein consist of alternating layers of very dense tungsten (W) absorber and scintillating crystal Lutetium Yttrium Orthosilicate LYSO(Ce) plates, assembled to a depth of 25 X-0. The scintillation signals produced by the EM showers in the region of EM shower maximum (shower max) are transmitted to SiPM located at the upstream/downstream ends of the modules via quartz capillaries which penetrate the full length of the module. The capillaries contain DSB1 organic plastic WLS filaments positioned within the region of shower max, where the shower energy deposition is greatest, then fused with quartz rod elsewhere. The wavelength shifted light from this spatially-localized shower max region is then propagated to the photosensors. This paper presents the results of an initial measurement of the time resolution of a RADiCAL module over the energy range 25 GeV <= E <= 150 GeV using the H2 electron beam at CERN. The data indicate an energy dependence of the time resolution that follows the functional form: sigma(t )= a/root E circle plus b, where a = 256 root GeV ps and b = 17.5 ps. The time resolution measured at the highest electron beam energy for which data was currently recorded (150 GeV) was found to be sigma(t) = 27 ps.

Tanım

Dergi veya Seri

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT

ISSN

0168-9002

ISBN

Alıntı

Koleksiyonlar

Onay

Gözden geçir

Tamamlayıcı Bilgiler

Referans Gösteren

Related Patent

Related Goal

0

Views

0

Downloads