Yayın: Simple Determination of Cystine in Artificial Urine and Drug Matrices Using Digital Image Colorimetry
| dc.contributor.author | Kustanto, Tulay Borahan | |
| dc.contributor.author | Zaman, Buse Tugba | |
| dc.contributor.author | Korkunc, Ummugulsum Polat | |
| dc.contributor.author | Gel, Mehmet Selim | |
| dc.contributor.author | Bakirdere, Sezgin | |
| dc.date.accessioned | 2026-06-27T15:21:05Z | |
| dc.date.issued | 2026 | |
| dc.description.abstract | Smartphone-based digital image colorimetry was developed for the determination of cystine in pharmaceutical formulations and artificial urine samples. A lab-made colorimetric box was designed for capturing the digital images of sample solutions using a smartphone. The developed method employs a simple colorimetric method called nitroprusside test which specifically targets free -SH groups. Cystine was reduced to cysteine before the colorimetric test was applied. The color intensity is inversely related to the concentration of the analyte. The best linearity was obtained with the G color channel. Digital image processing was performed using the RGB Color Detector mobile application to obtain analytical data. The developed method exhibited good linearity in the range of 29.7-00.3 mg/kg. The limits of detection and quantification were 9.7 mg/kg and 32.3 mg/kg, respectively. The percent recoveries were 104.2 +/- 7.8% and 108.7 +/- 4.6%, which proved the accuracy and applicability of the developed method. | en |
| dc.description.uri | https://doi.org/10.1080/00032719.2025.2517118 | |
| dc.identifier.doi | 10.1080/00032719.2025.2517118 | |
| dc.identifier.eissn | 1532-236X | |
| dc.identifier.endpage | 934 | |
| dc.identifier.issn | 0003-2719 | |
| dc.identifier.issue | 5 | |
| dc.identifier.startpage | 920 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14981/70063 | |
| dc.identifier.volume | 59 | |
| dc.identifier.wos | 001507358800001 | |
| dc.language.iso | eng | |
| dc.publisher | TAYLOR & FRANCIS INC | |
| dc.relation.ispartof | ANALYTICAL LETTERS | |
| dc.subject | Cystine | |
| dc.subject | determination | |
| dc.subject | digital image colorimetry | |
| dc.subject | smartphone | |
| dc.subject | spectrophotometry | |
| dc.subject | urine | |
| dc.subject | AMINO-ACIDS | |
| dc.subject | GOLD NANOPARTICLES | |
| dc.subject | CYSTEINE | |
| dc.subject | CHROMATOGRAPHY | |
| dc.subject | VALIDATION | |
| dc.subject | SAMPLES | |
| dc.subject | FLUIDS | |
| dc.subject | FILM | |
| dc.subject | Chemistry | |
| dc.title | Simple Determination of Cystine in Artificial Urine and Drug Matrices Using Digital Image Colorimetry | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| local.import.source | WOS |