Yayın: Discharge coefficient of a semi-elliptical side weir in subcritical flow
| dc.contributor.author | Kaya, Nihat | |
| dc.contributor.author | Emiroglu, M. Emin | |
| dc.contributor.author | Agaccioglu, Hayrullah | |
| dc.date.accessioned | 2026-06-27T13:14:48Z | |
| dc.date.issued | 2011 | |
| dc.description.abstract | A labyrinth weir is an overflow weir, folded in plan view to provide a longer total effective length for a given overall weir width. The total length of the labyrinth weir is typically three to five times the weir width. In this study, a semi-elliptical labyrinth weir was used as a side weir structure. Rectangular side weirs have attracted considerable research interest. The same, however, is not true for labyrinth side weirs. The present study investigated the hydraulic effects of semi-elliptical side weirs in order to increase their discharge capacity. To estimate the outflow over a semi-elliptical side weir, the discharge coefficient in the side weir equation needs to be determined. A comprehensive laboratory study including 677 tests was conducted to determine the discharge coefficient of the semi-elliptical side weir. The results were analyzed to find the influence of the dimensionless weir length L/B, the dimensionless effective length L/l, the dimensionless weir height p/h(1), the dimensionless ellipse radius b/a, and upstream Froude number F-1 on the discharge coefficient. It was found that the discharge coefficient of semi-elliptical side weirs is higher than that of classical side weirs. Additionally, a reliable equation for calculating the discharge coefficient of semi-elliptical side weirs is presented. (C) 2010 Elsevier Ltd. All rights reserved. | en |
| dc.description.sponsorship | Scientific and Technological Research Council of Turkey (TUBITAK) | |
| dc.description.uri | https://doi.org/10.1016/j.flowmeasinst.2010.11.002 | |
| dc.identifier.doi | 10.1016/j.flowmeasinst.2010.11.002 | |
| dc.identifier.eissn | 1873-6998 | |
| dc.identifier.endpage | 32 | |
| dc.identifier.issn | 0955-5986 | |
| dc.identifier.issue | 1 | |
| dc.identifier.startpage | 25 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14981/50995 | |
| dc.identifier.volume | 22 | |
| dc.identifier.wos | 000287567500004 | |
| dc.language.iso | eng | |
| dc.publisher | ELSEVIER SCI LTD | |
| dc.relation.ispartof | FLOW MEASUREMENT AND INSTRUMENTATION | |
| dc.subject | Side weir | |
| dc.subject | Discharge coefficient | |
| dc.subject | Intake | |
| dc.subject | Labyrinth | |
| dc.subject | Semi-elliptical | |
| dc.subject | Channel flow | |
| dc.subject | SUPERCRITICAL-FLOW | |
| dc.subject | Engineering | |
| dc.subject | Instruments & Instrumentation | |
| dc.title | Discharge coefficient of a semi-elliptical side weir in subcritical flow | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| local.import.source | WOS |