Yayın:
Reverse phase dispersive liquid-liquid microextraction coupled to slotted quartz tube flame atomic absorption spectrometry as a new analytical strategy for trace determination of cadmium in fish and olive oil samples

dc.contributor.authorOzzeybek, Gozde
dc.contributor.authorSahin, Ipek
dc.contributor.authorErarpat, Sezin
dc.contributor.authorBakirdere, Sezgin
dc.date.accessioned2026-06-27T14:28:13Z
dc.date.issued2020
dc.description.abstractIn the present study, trace level of cadmium was determined by a new, sensitive and simple analytical method called as reverse phase dispersive liquid-liquid microextraction (RP-DLLME) combined to slotted quartz tube flame atomic absorption spectrometry (SQT-FAAS) system. Microextraction parameters such as type and volume of disperser solvent, volume of extraction solvent, heating effect, initial sample volume, final volume, centrifugation period and type/period of mixing were optimized. FAAS and SQT-FAAS systems were also examined to get high signal to noise ratio. After optimizing all significant parameters, the limit of detection (LOD) and limit of quantification (LOQ) of the developed analytical strategy were calculated as 0.74 and 2.48 mu g/kg, respectively. In order to determine the applicability and accuracy of the RP-DLLME-SQT-FAAS method, recovery studies were performed in fish oil syrup. Matrix matching calibration strategy was used to eliminate heavy matrix effects on analytical signals, and percent recovery results were found between 95.6 and 105.7 %.en
dc.description.urihttps://doi.org/10.1016/j.jfca.2020.103486
dc.identifier.doi10.1016/j.jfca.2020.103486
dc.identifier.eissn1096-0481
dc.identifier.issn0889-1575
dc.identifier.urihttps://hdl.handle.net/20.500.14981/60970
dc.identifier.volume90
dc.identifier.wos000535704400010
dc.language.isoeng
dc.publisherACADEMIC PRESS INC ELSEVIER SCIENCE
dc.relation.conference12th International Food Data Conference (IFDC)
dc.relation.ispartofJOURNAL OF FOOD COMPOSITION AND ANALYSIS
dc.subjectCadmium
dc.subjectReverse phase dispersive liquid-liquid microextraction
dc.subjectAtomic absorption spectrometry
dc.subjectSlotted quartz tube
dc.subjectPRECONCENTRATION
dc.subjectSOLVENT
dc.subjectHEALTH
dc.subjectCHROMATOGRAPHY
dc.subjectEXTRACTION
dc.subjectChemistry
dc.subjectFood Science & Technology
dc.titleReverse phase dispersive liquid-liquid microextraction coupled to slotted quartz tube flame atomic absorption spectrometry as a new analytical strategy for trace determination of cadmium in fish and olive oil samples
dc.typeArticle; Proceedings Paper
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar