Yayın:
Simultaneous voltammetric analysis of lead, copper and mercury ions by carbon paste electrode based on 1-(3-aminopropyl) imidazole modified polymer

dc.contributor.authorBayraktar, Cansu
dc.contributor.authorCankurtaran, Husnu
dc.contributor.authorSenkal, Bahire Filiz
dc.date.accessioned2026-06-27T14:15:10Z
dc.date.issued2018
dc.description.abstractIn this study, a carbon paste electrode modified with a novel 1-(3-aminopropyl) imidazole functionalised crosslinked chlorosulfonated poly(styrene)-divinyl benzene polymer was used for selective and sensitive determination of the trace amounts of Pb2+, Cu2+ and Hg2+ ions by square wave anodic stripping voltammetry. The effect of some parameters such as paste composition, pH, preconcentration time, reduction potential and time, type of supporting electrolyte and potential scan rate on the determination of metal ions were investigated to find the optimal conditions. The effective open-circuit accumulation of the studied metal ions was succeeded only by the modification of the carbon paste electrode with functional polymer. For 6min open-circuit preconcentration, the detection limit of Pb2+, Cu2+ and Hg2+ was found to be 5, 9 and 14 mu gL(-1), respectively at 100mVs(-1). The results confirmed that the lower concentration levels of these trace metal ions can be determined with the increase of preconcentration time and/or potential scan rate. Good detection limits and large dynamic concentration ranges were also obtained for their binary and ternary mixtures. The optimised method was successively applied to determine the concentration of Pb2+, Cu2+ ions in the tap water sample and Cu2+ ion in the waste water sample in the presence of possible interfering species (RSD<1%, recoveries 96-110% for 4min preconcentration).en
dc.description.urihttps://doi.org/10.1080/03067319.2018.1515355
dc.identifier.doi10.1080/03067319.2018.1515355
dc.identifier.eissn1029-0397
dc.identifier.endpage906
dc.identifier.issn0306-7319
dc.identifier.issue10
dc.identifier.startpage889
dc.identifier.urihttps://hdl.handle.net/20.500.14981/58476
dc.identifier.volume98
dc.identifier.wos000445799400001
dc.language.isoeng
dc.publisherTAYLOR & FRANCIS LTD
dc.relation.ispartofINTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY
dc.subjectCarbon paste electrode
dc.subjectanodic stripping
dc.subjecttrace metal ions
dc.subjectlead
dc.subjectcopper
dc.subjectmercury
dc.subjectCHEMICALLY-MODIFIED ELECTRODES
dc.subjectANODIC-STRIPPING VOLTAMMETRY
dc.subjectWATER SAMPLES
dc.subjectONLINE PRECONCENTRATION
dc.subjectMETAL-IONS
dc.subjectHG(II)
dc.subjectCADMIUM(II)
dc.subjectPB(II)
dc.subjectACID
dc.subjectSILVER(I)
dc.subjectChemistry
dc.subjectEnvironmental Sciences & Ecology
dc.titleSimultaneous voltammetric analysis of lead, copper and mercury ions by carbon paste electrode based on 1-(3-aminopropyl) imidazole modified polymer
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar